60
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
Table 20: Msg sent 24h submenus
Menu
Description
1.2.8.9.1 All SMSes
All messages.
1.2.8.9.2 Report SMSes
Reporting messages.
1.2.8.9.3 Unknown SMSes
User SMS control messages that were not recognized and
therefore forwarded to the Supervisor.
Note:
This counter works only if the SMS forwarding is enabled.
See “9.3.n.6.2 SMS forwarding” on page 183.
1.2.8.10 Battery status
10>Battery stat.
OK
The informational screen shows the GSM module battery status.
Battery status should be OK. If the battery is faulty or missing, the battery status
is Fail.
1.2.9 Battery test
1>Test options
2 Man. bat. test
This menu allows you to perform a manual battery test as well as configure an
automatic test for batteries in the panel or an expander.
Notes
• This functionality is available only in specific devices, for example, ATS120xE
expanders.
• Battery test works only if there is no mains fault present.
1.2.9.1 Test options
1>Panel
3 Exp
Use this menu to configure an automatic battery test.
First, select the panel or an expander to test the battery.
1.2.9.1.m Select device type
1>Expander 1
2 Expander 2
Select the appropriate device group.
1.2.9.1.m.n Select device
1>Test time
10
Select the appropriate device.