1  IF-800/W02 Terminal (Slave) 

Thank you for choosing an Interflex system. With this slave terminal, you 
have purchased a reliable device for access control. 

 

Scope of delivery:   

The following is included in the package: 

 

W02 housing cover 

 

Reader housing with encapsulated RFID electronics and 5 m connecting 
cable 

 

I/O controller board with address switch 

 

Mounting plate for fastening 

 

Material for wall mounting 

 

  Please check the completeness and condition of the shipment upon 

receipt. 

 

 

 

 

2  Function 

Slave terminals of series IF-800 W02 are used for: 

1.  controlling the access of people who identify themselves via an RFID credential before entering a 

security zone. 

2.  controlling and monitoring locking devices that prevent uncontrolled (physical) access to security zones. 

3.  writing NetworkOnCard access rights. The data is used for identification at offline devices, e.g. PegaSys 

terminals. 

 

A higher-ranking device, such as a terminal controller or a master terminal, is required for operation. 

 

95-10327_ V2016-10-20 IF800_W02 

IF-800/W02 

 

Содержание IF-800/W02

Страница 1: ...l mounting Please check the completeness and condition of the shipment upon receipt 2 Function Slave terminals of series IF 800 W02 are used for 1 controlling the access of people who identify themsel...

Страница 2: ...sfer problems must be examined on a case by case basis Where necessary a shielded cable must be used for the corresponding devices 5 How to Proceed During Installation The following installation proce...

Страница 3: ...aid in empty conduit 100 m 4 x 2 x 0 6 mm 2 Control line for electric actuator No specifications 2 x 2 x 0 6 mm 3 Cable to door sensor handle contact or opening push button 100 m 2 x 2 x 0 6 mm 4 RS48...

Страница 4: ...ID readers When the device is mounted on a metal surface the reading distance is reduced Close housing The housing cover 3 is first placed over the reader electronics during initial operation To close...

Страница 5: ...gs check the BUS address section of the higher ranking device such as e g a master terminal You can do so by using a remote program e g Telnet and entering the OC command cfg Furthermore please check...

Страница 6: ...r master terminal please refer to the installation and wiring instructions included in the delivery of the respective device 1 IF 800 W02 6 Example Door monitoring connection 2 I O controller board 7...

Страница 7: ...Protection Protection category III Degree of protection Reader IP65 encapsulated electronics I O board IP 00 General Data Ambient temperature 25 C to 55 C Humidity Max 95 non condensing Product safety...

Отзывы: