background image

 

 

Scape® 

Pro 

spr65-005

 

 

 

Operating Manual 

 

 

Содержание Scape Pro spr65-005

Страница 1: ...Scape Pro spr65 005 Operating Manual ...

Страница 2: ...__________________ 13 3 1 Notes ________________________________________________________________________________________________________________13 3 2 Connection to the power supply_____________________________________________________________________________________13 3 3 Connection to the network __________________________________________________________________________________________13 4 Switch...

Страница 3: ..._________________________________________________________21 8 2 3 Front view_______________________________________________________________________________________________________ 22 8 2 4 Right view_______________________________________________________________________________________________________ 23 8 2 5 Detail Tube with table legs_____________________________________________________________...

Страница 4: ...esired operation This Class A digital apparatus complies with Canadian ICES 003 This manual is applicable for the following devices Scape Pro 65 spr65 005 with st65 004 R1 1 and pcsi 005 Information in this document is subject to change without notice 2019 Interactive Scape GmbH All rights reserved The document or excerpts from the document may not be duplicated without the prior permission of Int...

Страница 5: ...sion cords and power strips can cause fire and electric shock Avoid using power strips and extension cords if possible Do not chain multiple extension cords or power strips together Overheating Heat build up can overheat the screen and the integrated PC This can damage the device Ensure there is sufficient air circulation around the Scape Pro Make sure all the ventilation holes on around the scree...

Страница 6: ...rs medical practices and other medical facilities to avoid interference with sensitive medical equipment Check with your doctor or the manufacturer of your medical device pacemaker hearing aid implant with electronic control etc to see if it can work your Scape Pro without interference If necessary maintain the minimum distance of 15 cm recommended by medical device manufacturers to avoid interfer...

Страница 7: ...cleaning Typically a solution of isopropyl alcohol and water 50 50 blend ratio or the included screen cleaning kit are best for cleaning the touch sensor Apply the solution to a soft lint free cloth Avoid using rough cloths Use the cloth to clean the glass surface Apply the liquid only to the cloth and never directly to the device This will prevent liquid from entering the inside of the device or ...

Страница 8: ...egrated PC Touchscreen Connections powerCON TRUE1 input and output 2x USB 3 0 1x USB 2 0 1x HDMI 2 0 1x Ethernet 1x Connector for external WLAN antenna Zotac Silent PC 2 4 4 1 GHz Intel Core i5 9300H NVIDIA GeForce RTX 2060 6GB 16 GB RAM 256 GB SSD Operating System Windows 10 Professional Display 3840 x 2160 UHD 60 Hz 16 7 million colors 8 ms response time Touch sensor 3M PCAP 80 Touches optional ...

Страница 9: ...he device Loosen the two 2 5mm hexagon socket screws on the lower cover on the inside of the PC unit to expose the connections The cover plate is designed in such a way that there is sufficient space to reattach it after all cables have been connected After all the cables have been connected reattach the plate to the PC unit to protect the connections and prevent unintentional removal of the cable...

Страница 10: ...ubject spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 10 of 27 poc SFi 2 2 2 Connections for power and peripherals 4 USB 3 0 type A 5 USB 3 0 type A 6 HDMI 2 0 7 RJ45 network connection 8 powerCON TRUE1 Power supply input and output ...

Страница 11: ...gous to button on remote control 1 IR Sensor for remote control 2 Switch between Touch TUIO USB Touch 3 RJ 45 Lan interface to use the Capore Touch Object Assistant 4 USB Connection Type B for direct connection of touch and PC 5 DisplayPort input 6 HDMI 2 0 input UHD 60 Hz 7 HDMI input 8 DVI input 9 Stand by 17 10 Status LED 11 Close OSD back show input selection 21 12 Plus Right 23 13 Minus Left ...

Страница 12: ...27 poc SFi 2 2 4 Remote control analogous to button on the screen All keys on the remote control which are not explained above are not required for operation of Scape Pro and do not have any function 17 Stand by 9 18 Display mode selection 19 Show input selection 20 Show OSD confirm selection 14 21 Close OSD 11 22 Left Minus 13 23 Right Plus 12 17 18 19 20 21 22 23 ...

Страница 13: ...it is connected Finally plug the earth contact plug into a suitable socket To disconnect the power supply pull the lock on the powerCON plug downwards turn the plug 45 anticlockwise and pull it downwards out of the powerCON socket When disconnecting the appliance from the mains always pull the plug and do not pull the cable Do not touch the plug with wet hands 3 3 Connection to the network The Sca...

Страница 14: ...ay when the device is switched on Do not touch the touch screen during device startup otherwise there will be errors in the touch and object detection The device will take about 1 5 hours to power up before it reaches its final operating temperature During this time the touch sensor of the device constantly adapts to its environment This has a direct effect on long term object recognition If your ...

Страница 15: ...s for each setting or to select the appropriate option The Menu 20 button activates the selected option and returns to the last selection level The Exit 21 button resets the setting to its original value and returns to the next higher menu level or closes the OSD when you are at the top menu level The OSD automatically shuts off after a few seconds of inactivity Abb 1 Menu opened select menu item ...

Страница 16: ... the operating system and its components To do this use the Windows backup tools backup settings Your Scape Pro with integrated PC comes with a wireless keyboard with integrated trackpad Follow the enclosed instructions to use the keyboard To switch on the integrated PC press the power button on the back of the PC unit see Chapter 2 2 1 PC unit Item 1 A system user with administrator rights and th...

Страница 17: ...urer Support Interactive Scape GmbH Wilhelmine Gemberg Weg 6 10179 Berlin 49 0 30 698 094 150 7 2 Problems and solutions Error Possible cause Possible solution No picture is shown even though the PC is turned on The DisplayPort or HDMI cable has come loose Check the connection of the cable with the PC Plug the cable into another connector on the PC The screen is switched to the wrong input Set the...

Страница 18: ... K240 Display diagonal 1547 x 922 x 920 mm Resolution 3840 x 2160 UHD Brightness panel 700 cd m Contrast panel 3000 1 Backlight LED Viewing angle 178 178 Color gamut 16 7 million Latency 8 ms Backlight lifetime 60 000 h Pixel class ISO 9241 307 Pixel Error Class II Touch controller 3M PCAP 80 touches Palm recognition Object recognition possible Capore Interfaces Touch HID USB TUIO 1 1 Operating pe...

Страница 19: ...oling 0 5 m min Material Sheet steel Powder coated fine structure deep black RAL9005 Specifications Processor Intel Core i5 Quad Core RAM 16 GB Hard drive 250 GB SSD Samsung M 2 Graphics card NVIDIA Geforce RTX 2060 6GB Ports Display 2x HDMI 2 0 2x DisplayPort 1 3 Network WLAN 802 11ac b g n Bluetooth 4 2 2x Gigabit Ethernet USB 2x USB 3 0 2x USB 2 0 1x USB 3 1 1x USB 3 1 type C Other Dimensions L...

Страница 20: ...8 Appendix Scape Pro Technical specifications are subject spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 20 of 27 poc SFi 8 2 Technical drawings 8 2 1 Perspective ...

Страница 21: ...8 Appendix Scape Pro Technical specifications are subject spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 21 of 27 poc SFi 8 2 2 Top view ...

Страница 22: ...8 Appendix Scape Pro Technical specifications are subject spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 22 of 27 poc SFi 8 2 3 Front view ...

Страница 23: ...8 Appendix Scape Pro Technical specifications are subject spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 23 of 27 poc SFi 8 2 4 Right view PC tube ...

Страница 24: ...8 Appendix Scape Pro Technical specifications are subject spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 24 of 27 poc SFi 8 2 5 Detail Tube with table legs ...

Страница 25: ...ct spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 25 of 27 poc SFi 8 2 6 Detail Tube 1 On Off switch 2 WLAN antenna connection SMA with WLAN antenna USB 2 0 type A 3 Cover plate for power and peripheral connections 1 2 3 ...

Страница 26: ... spr65 005 to change without notice Operating Manual Version 1 6 Status 12 2019 Page 26 of 27 poc SFi 8 2 7 Detail Tube connections 4 USB 3 0 type A 5 USB 3 0 type A 6 HDMI 2 0 7 RJ45 network connection 8 powerCON TRUE1 Power supply input and output 4 5 6 7 8 ...

Страница 27: ...Interactive Scape GmbH Wilhelmine Gemberg Weg 6 D 10179 Berlin T 49 30 69 809 41 00 F 49 30 69 809 429 www interactive scape com info interactive scape com ...

Отзывы: