Operation Manual
Emergency Combination System
ECS-6216MS
* Rack mount products in the Western Hemisphere(North America, South America, and the Caribbean)
do not have handles installed due to customer preference.
Страница 1: ...ration Manual Emergency Combination System ECS 6216MS Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preferen...
Страница 2: ...e AC Cord The socket outlet shall be installed near the equipment and shall be easily accessible CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk...
Страница 3: ...Installation Environment 2 Important Safety Instructions 2 Features 3 Equipment Setup and Inspection 4 Front Panel 5 Rear Panel 6 Applications 9 Block Diagram 10 Specifications 11 Service 12 Procedur...
Страница 4: ...s or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A g...
Страница 5: ...UAL BROADCAST CONTROL It can control the broadcasting of the channel you want by controlling the switches on the front side CONTROL THE 3 LINE TYPE SPEAKER TRACK It consists of the channels for the co...
Страница 6: ...s of set equipment are as follow 2 TERMINATION Switch LOAD OPEN Setting 1 Termination switch on the rear panel should be set Load Open to stabilize the data transfer in case of the system linked by us...
Страница 7: ...ill be on the zone selected by the button which selects the individual broadcasting zone For emergency broadcast ES red light will be pm and green will be on for the common broadcast PS The zone broad...
Страница 8: ...will be transmitted to number 1 2 and 3 zones in a same time 2 PD COM TERMINAL 1 It is the contact point output terminal used for controlling the operations of the power distributor If speaker zone is...
Страница 9: ...Equipment products which have RS 232 communication terminal 2 Maximum communication distance is about 12 meter 3 PIN OUT Specification 7 SPEAKER OUT TERMINAL It is the terminal which connects the chan...
Страница 10: ...CY COMBINATION SYSTEM 8 ECS 6216MS 10 POWER INPUT TERMINAL It is the power input terminal Caution to polarity and connect DC 24V If it is connected with PD POWER DISTRIBUTOR connect it to UNSWITCHED T...
Страница 11: ...NN EXT INT AUTO ANN REMOTE MIC MIC SW EXT INT HPF ON OFF AC INPUT FUSE DC INPUT 24V BALANCED INPUT 1V 10K LINK INPUT ADJ 12dB 0dB 100V 20 8 43 8V 4 OUTPUT COM A B 70V 10 2 FRAME FLOAT GROUND LIFT INPU...
Страница 12: ...S SWITCH TIMER INPUT EXT INPUT KEY INPUT AMP INPUT CH1 AMP INPUT CH2 AMP INPUT CH16 FIRE CONTACT INPUT CH1 16 RELAY CONTROL MCU EP CONTROL JACK RS232 COMM PORT1 RS232 COMM PORT2 RS485 COMM RS485 TERMI...
Страница 13: ...ce File RS 232 12m Fire Sensor Dry Contact Operating Temperature 10 C 40 C 14 F 104 F Power Source DC 24V 600mA Weight Set 4 3kg 9 5lbs Dimensions Set 482 W x88 H x280 D mm 19 W x3 5 H x11 D in Specif...
Страница 14: ...ranty Warranty Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating the appro...
Страница 15: ...EMERGENCY COMBINATION SYSTEM 13 ECS 6216MS...
Страница 16: ...mpany but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more...