background image

 

 

 

13

 

3.2.8.

 

Image enhancement setup 

Setup:   

Press

  MENU

  button

 

until

  E:  XXX

  option  is  selected.

 

Press

  UP

  button

 

or 

DOWN

 

button

 

to set needed enhancing state.

 

Exit:            Press 

MENU

  button  until 

Exit

:  option  is  selected  and  press 

UP 

button  or

  DOWN 

button to exit. 

Note:

  Image  enhancement  can  improve  the  observation  effect,  but  may  decrease  the 

Signal-to-Noise. This function is disabled in Mode 8. 

3.2.9.

 

  Crosshair setup 

Setup:

 

Press 

MENU 

button  until 

C:  XXX

  menu  option  is  activated;  Press

  UP 

button  or 

DOWN 

button to setup needed enhancing state. 

Exit:

            Press 

MENU

  button  until 

Exit

:option  is  selected  and  press 

UP 

button  or

  DOWN 

button to exit. 

Note: 

Set the calibration parameter if the images are non-uniformity 

3.2.10.

 

  Dead pixel correction setup 

Setup: 

Manually  Setup:

  press 

button  and 

UP 

button

 

at  the  same  time  to  activate  dead 

pixel correction setup. Press 

UP 

button or 

DOWN 

button

 

to move crosshair central 

dot to dead pixel position, and then press 

button (calibration function) to replace 

current dead pixel (press 

C

 button

 

again to cancel). 

Exit

:            Press 

MENU 

button to select 

Esc

, and then press 

UP 

button

 

to exit.   

Note: 

If  immovable  dead  pixel  exists  in  the  image,  calibration  can  not  be  done  by  pressing 

button to activate dead pixel correction setup. 

Содержание ThermalTronix TT-1040S-UTCM

Страница 1: ...ThermalTronix TT 1040S UTCM TT 1075S UTCM Thermal Imaging Camera User Manual...

Страница 2: ...If the internal connection is broken during the assembly process or the apparatus is damped rain wet the performance will be reduced and even the device will be damaged Make sure that the power contro...

Страница 3: ...7 3 1 2 System menu 9 3 1 3 Communication menu 9 3 1 4 Mode menu 10 3 2 Main operation description 10 3 2 1 Focusing 10 3 2 2 Single pixel correction setup 10 3 2 3 Auto imaging mode setup 11 3 2 4 Im...

Страница 4: ...3 1 Overview The Figure 1 1 shows the overall dimension of the camera Figure 1 1 Overview of the camera Figure 1 2 Back of the camera...

Страница 5: ...ke out the camera and other accessories 4 Connect the video connector to the monitor 5 Connect the power adapter and power cable 6 Connect the power cable to the power supply to power on the camera 2...

Страница 6: ...When the menu is not activated press DOWN to focus backwards M MEMU key Press to activate or hide the menu Press MENU to select the parameter and modify the parameter value via UP or DOWN keys Continu...

Страница 7: ...BNC video output interface 2 3 2 Multiple interface Figure 2 3 2 1 Multiple interface The definition of each pin is as below No Pin name Description 1 12V Positive power input 2 GND Power ground 3 RS4...

Страница 8: ...tion is selected and press UP button or DOWN button to exit Figure 3 1 1 1 Main menu interface Auto XXX Display the current image auto mode Three options 0 manual gain manual brightness 1 manual gain...

Страница 9: ...range 0 255 B XXX Brightness value range 2048 2048 P XXX White black hot display mode 0 black hot 1 white hot Z XXX Zoom status 1 No zoom 2 2X E XXX Image enhancement status Y on N off C XXX Display...

Страница 10: ...menus setting for factory default Exit Exit setting menu Press MENU button to select the Exit option and press UP button to exit the menu 3 1 3 Communication menu In System menu press M button to sel...

Страница 11: ...til Exit option is selected and press UP button or DOWN button to exit 3 2 Main operation description 3 2 1 Focusing When there is no menu displayed press UP or DOWN button to adjust the focus or pres...

Страница 12: ...ightness and gain automatically according to the observed object Auto 1 Manual gain auto brightness The camera adjusts brightness automatically according to the observed object and you may adjust gain...

Страница 13: ...MENU button until B XXX option is selected Press UP button or DOWN button to adjust brightness parameter value Exit Press MENU button until Exit option is selected and press UP button or DOWN button...

Страница 14: ...ng state Exit Press MENU button until Exit option is selected and press UP button or DOWN button to exit Note Set the calibration parameter if the images are non uniformity 3 2 10 Dead pixel correctio...

Страница 15: ...not power on Power cable is not connected correctly Connect the power cable again Thermal camera protection procedure Wait for 10 seconds and turn on again The camera powers off automatically The powe...

Страница 16: ...s Brightness gain Manual brightness gain Automatic brightness manual gain Automatic brightness gain Automatic brightness gain configuration adjustment 2 fixed patterns 8 user defined modes Polarity re...

Страница 17: ...16 Power supply Power consumption 6W Interface External power YES DC12V 20 Video output PAL Communication interface RS485 Control protocol PELCO D PELCO P INTELLISYSTEM...

Отзывы: