background image

 
 
 

 
 
 

7

 

 

LED Indicators

 

LED indictor light on the front panel of product, the function of each LED is described in the table as below.  

System Indication LED 

LED 

State   

Description 

PWR 

(P1, P2) 

ON 

Power is being supplied to 

power input PWR input 

OFF 

Power is 

not

 being 

supplied to power input 

PWR input 

RUN 

ON/OFF  System is not running 

well 

Blinking  System is running well 

Link/ACT 

(1~16) 

ON 

Port connection is active 

Blinking  Data transmitted 

OFF 

Port connection is not 

active 

Installation

 

Before installation, confirm that the work environment meet the installation require, including the power needs  and abundant space. 

Whether it is close to the connection equipment and other equipments are prepared or not.   

1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 

3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.   

4. Power: 12~48VDC power input 

5. Environment

working temperature -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

 

DIN-rail installation 

In order to apply for industrial environments conveniently, IES6116 series adopts 35mm  DIN-Rail installation, the installation steps 

are as follows: 

1.

 

Examine the DIN-Rail accessories 

2.

 

Examine DIN Rail is firm or not and the position is suitable or not. 

3.

 

Insert the top of the DIN-Rail into the slot just below the stiff metal spring. 

4.

 

The DIN-Rail attachment unit will snap into place as shown below.   

Содержание IT-ES3016-IU Series

Страница 1: ...roduct accorded to CE FCC standard and Industry grade 4 design requirement support 2 redundant power input and 40 75 working temperature can meet all kinds of Industrial environment requirement It can...

Страница 2: ...ES3016 IU P 12 48VDC 1 Systems running LED 2 The power LED 3 Relay alarm LED Retain 4 Link ACT LEDs 5 10 100BaseT X RJ45 ports 7 Power input terminal block 8 Ground screw 9 Relay output terminal bloc...

Страница 3: ...l block 8 Ground screw 9 Relay output terminal block 10 Console port 11 DIP switch 12 DIN Rail mount IT ES3016 IU 4F P 12 48VDC 1 Systems running LED 2 The power LED 3 Relay alarm LED 4 Link ACT LEDs...

Страница 4: ...rew 9 Relay output terminal block 10 Console port 11 DIP switch 12 DIN Rail mount IT ES3016 IU 8F P 12 48VDC 1 Systems running LED 2 The power LED 3 Relay alarm LED 4 Link ACT LEDs 5 10 100BaseT X RJ4...

Страница 5: ...er port then insert power supply plug into power source 2 Power OFF operation First off all unpin power plug then strike the terminal block please take care of operation sequence Appearance and dimens...

Страница 6: ...Fiber port 100Base FX full duplex SM or MM port SC ST FC type The fiber port must be used in pair TX transmit port connect remote switch s RX receive port RX receive port connect remote switch s TX tr...

Страница 7: ...n equipment and other equipments are prepared or not 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in intense EMI 2 Examine the cables and plugs that installation requ...

Страница 8: ...lines Cables power lines and grounding lines cannot be overlapped and mixed when they are in the same groove road When cable is too long it cannot hold down other cable but structure in the middle of...

Страница 9: ...d consumption 4 83W 24VDC Full load consumption 7 30W 24VDC IT ES3016 IU 2F P 12 48VDC Unload consumption 6 12W 24VDC Full load consumption 8 33W 24VDC IT ES3016 IU 4F P 12 48VDC Unload consumption 7...

Страница 10: ...000 4 2 ESD Level 4 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 4 EN61000 4 5 Surge Level 4 EN61000 4 6 CS Level 3 EN61000 4 8 Level 5 Shock IEC 60068 2 27 Free fall IEC 60068 2 32 Vibration IEC 6006...