IntelliSense MC-550 Скачать руководство пользователя страница 1

Figure 4  Changing the Lens

WIRING

Terminals TB1 and TB2 (MC-550T only) are located at the top edge of
the PCB.  Wire the MC-550 / MC-550T as shown in Figure 3 using 14-
22 AWG wire.  After the wiring is complete, push as much of the wire
as possible back into the wall.

®

For proper wiring methods, refer to the National Electrical Code, NFPA 70.

To install the optional pet-alley lens*:

• Remove the front cover of the

MC-550 / MC-550T. (See Fig-
ure 1.)

• Press up on the Bug Guard

latch and then pull the Bug
Guard out of the front cover

.

• Remove the existing lens, and

place the new lens in with the
SMOOTH side facing outward.

• Install the lens with the small

slot at the  top and the large
slot at the bottom.

CHANGING THE FRESNEL LENS

Figure 5 Printed Circuit Board

TB1

+1

0

Self T

e

s

t

High

Normal

K1

Low

No jumper

NC

C

TB2

S1

TMPR

LED
Enable

J3
J1

ALIGNMENT NOTCH

DS1 (Alarm LED) illuminates
when an alarm condition is
triggered.

Jumper position J1  on the PCB
is used to set the sensitivity of
the PIR detector.

Using the chart below, configure
the MC-550 / MC-550T for the
sensitivity best suited to your
application.

Normal  (PC3)

Jumper center & bottom pins

High (PC2)

Jumper top & center pins

Low (PC4)

Parked on one pin or off

A sensitivity setting of low is not recommended when run-through perfor-
mance is required.

Note:  Do not mount the unit at 10 feet / 3 m when using the low
sensitivity setting.

LOOK-DOWN WINDOW

SMALL SLOT

LARGE SLOT

BUG
GUARD

BUG GUARD
LATCH

 ALIGNMENT NOTCH
Important:  Align with appropriate
notch on the PCB (refer to Range
Chart on the next page).

-1

Install jumper at J3 to enable
Alarm LED (DS1). 

Jumper is

factory installed.
(MC-550T Only)

SENSITIVITY

JUMPER J1

Figure 3
Wiring

TAMPER

24 VDC

25mA

(MC-550T Only)

POWER

12 VDC

20mA

ALARM

24 VDC

100mA

TB2

TB1

• Install the look-down mask (optional) over the inside

of the look-down window.

• Place the Bug Guard into the look-down window then snap the Bug

Guard back into place.

• Reassemble the housing.

PIR SENSITIVITY

Important:  When using pet-alley lens, optimum mounting height is 4
feet / 1.2 m and adjust PCB to +1 position.

*Lens Option Kit Part Number 0-000-012-01

Microcontroller Based

Passive Infrared

Motion Sensor

Range: 50' x 40'

15 m x 12 m

INSTALLATION INSTRUCTIONS

Models

M C - 5 5 0

M C - 5 5 0 T

LATCH

PCB
LATCH

LATCH
RELEASE
SLOT

WIRE
ENTRY
KNOCK-
OUTS

Figure 2    Rear Housing

LATCH
RELEASE
SLOT

Figure 1    Opening the
MC-550/
MC-550T

ALIGN WITH
NOTCH IN PCB

FOR CORNER
MOUNTING

FOR
OPTIONAL
SWIVEL
MOUNT
BRACKET

• 50' x 40' / 15 m x 12 m range
• Dual element PIR
• Dense detection pattern
• Wide angle optics
• Low 20 mA current draw at

12  VDC

• 10-14  VDC operation
• Zone finder
• Energized form A alarm relay

FEATURES

• Microcontroller signal

processing

• Temperature compensation
• Diagnostics
• RF and white light immunity
• Selectable PIR sensitivity
• Mounting flexibility: on walls or

in corners

• Bug proof

The MC-550 / MC-550T is designed for use indoors.  Make sure the
sensor has a clear line-of-sight to the protected area.  Infrared energy
cannot penetrate solid objects.  If the sensor is blocked, it will not
alarm.

Aim the sensor toward the interior of the room, away from windows
and heating/cooling sources.   The unit can be corner or wall mounted
at either 4' / 1.2 m, 7'6" / 2.3 m, or 10' / 3 m (see Range Chart on
the next page).

MOUNTING LOCATION

False alarm immunity from small animals with the MC-550/550T can
be expected in installations with:

Any number of cats (or similar sized animals)*

Any number of birds, confined to a cage

Birds flying randomly though a warehouse setting

Any number of rats*

*The total weight of animals cannot exceed 15 pounds / 7 Kg.

For false alarm immunity with the above mentioned animals the
following installation procedures must be observed:

Use the standard wide angle lens optics

Mount the sensor at 7'6" or 10' / 2.3 or 3 m

Set the PIR pulse count at normal (PC3) or low (PC4)

Make sure no animal(s) can get within 6' / 1.9 m in the sensor's
direct line-of-sight.

MOUNTING PROCEDURE

Prepare the sensor for mounting
by removing the front  cover and
printed circuit board (PCB).

To remove the front cover of
the sensor, use a screwdriver
to slide into the latch release
slot located at the top of the
unit and then gently push up.
(See Figure 1.)

To remove the PCB, press
the latch holding the PCB in
place and gently pull up on
the PCB until it releases.
(See Figure 2.)

Using the rear housing
a s   a   t e m p l a t e ,   m a r k
mounting and wire access
locations.  Pull several
inches of wire into the
housing and fasten the
rear housing to the wall.

(Pulse count 2)

(Pulse count 3)
(Pulse count 4)

Отзывы: