Step 1

Separate sensor housings.

Use a small screwdriver to push in and

down on the latch at the top of the

sensor, and separate the housings.

Step 2

Remove the Printed Circuit Board.

Press outward on the latch on the right

side of the housing. Then gently pull the

printed circuit board (PCB) outward to the

left.

Step 3

Mount the sensor.

Carefully  break  out  the  mounting/wiring

knockouts on the rear housing, and mount

the housing in the desired location.

Step 6

Walk-test the sensor.

Apply power and let the sensor warm up

for three minutes.
Use the dip switches to test the PIR and

microwave technologies separately and

together.

NOTE:

  After 10 minutes of switch inactivity, the sensor

will revert to normal (alarm) mode, regardless of switch

positions.  When any switch is toggled, the 10 minute

timer resets.

Step 4

Wire the sensor.

Observing the proper polarity, wire the

unit as shown (use 14 to 22 AWG).

DT-700 

Series 

DUAL 

TEC

®

 Motion 

Sensor 

Installation 

Instructions

Tamper

50 mA,

24 VDC

Alarm

500 mA,

30 VDC

Power

35 mA,

7.5 - 16 VDC

(UL: 8.9 - 14.5 VDC)

Tamper

50 mA,

24 VDC

Alarm

500 mA,

30 VDC

Power

35 mA,

7.5 - 16 VDC

(UL: 8.9 - 14.5 VDC)

Remote

LED

Enable

Remote

LED

Enable

Wall Mount

Knockouts

Corner  Mount

Knockouts

Wiring

Knockouts

Wall Mount

Knockouts

Maximum  range  is  obtained  at  a  mounting

height of 2.3 m (7'6")

.   Make sure the sensor has

a  clear  line-of-sight  to  all  areas  you  wish  to

protect. If the PIR or microwave is blocked, the

unit will not alarm.
Aim the sensor toward the interior of the room,

pointing away from windows, moving machin-

ery,  fluorescent  lights,  and  heating/cooling

sources.

Reverse polarity will not damage the sen-

sor.

NOTE:   

For  proper  wiring  methods,  refer  to  the

National Electrical Code, NFPA 70.

Step 5

Reassemble the sensor.

After wiring the sensor, return the PCB to

the rear housing and snap the front hous-

ing back in place.

Walk across the protected area at the ranges

to be covered.  Two to four normal steps

should make the LED light.  When there is no

motion in the protected area, the LED should

be off.

Step 8

Set sensor polarity.

Switch S1, position 3 allows you to set

the sensor polarity to disable the LED

when the system is armed.  If the

control panel's output goes to negative

voltage (0 to +2V) when armed, the

switch should be in the – position

(OFF); if the panel's output goes to

positive voltage when armed (+3 V to

+24 V), the switch should be in the +

position (ON).

SW1-3

Polarity LED Disable

+ LED

Positive Voltage (+3 V to +24 V)

–  LED

Negative Voltage (0 to +2 V)

NOTE: 

 If the LED Enable terminal is not connected or

open  circuit,  the  LED  is  Enabled,  unless  the  LED

Disable switches are OFF.

To walk-test the microwave:

To walk-test the PIR:

Walk-test the microwave and PIR together.

This is the normal (alarm) mode.  Both must

trip for the sensor to alarm.

To walk-test both technologies together:

Step 7

Adjust the microwave range.

A.  Turn the microwave range

thumbwheel (R1) 

counterclockwise

to decrease the microwave range to

minimum

.  

(Range is factory set at

maximum.)

B.   As you perform the walk-test, gradually

turn the thumbwheel clockwise until the

desired range is obtained.

To disable the LED:

PIR range is determined by the mounting

height and angle, or by masking specific

PIR zones.

NOTE:  It is important to adjust the microwave range

to fit room size and characteristics.  Reflective surfaces

(i.e. metal shelving, concrete floors, glass, etc.) in-

crease sensitivity.