Calibrating Metropolix Outputs
You can calibrate all four of Metropolix’ variable outputs (
TRK 1 PITCH
,
TRK 2 PITCH
,
OUT A
,
OUT B
) using the same technique.
TIP : If you make a mistake at any point during the following calibration procedure, you can scroll to
the bottom of the Calibration menu, select Reload All , and press the encoder. This will reload the
current, previously saved values back into Metropolix. Once you enact a Save All , this is no longer
possible, since your edited values will overwrite the previous calibration.
To Calibrate Metropolix’ Outputs:
1.
Patch the
OUT A
into a calibrated voltmeter with .001V accuracy.
2.
Enter Calibration Mode, as discussed earlier.
3.
Turn the encoder to highlight ‘
OUT A 0V: [number]
’
, then press the encoder.
The
[number]
field is highlighted.
4.
Turn the encoder (either clockwise or counterclockwise) to adjust the internal trim
[number]
until
your voltmeter reads as close to 0.000V as possible, then press the encoder to lock in the
offset.
5.
Turn the encoder to highlight ‘
OUT A 1V: [number]
’, then press the encoder.
The
[number]
field is highlighted.
6.
Turn the encoder (either clockwise or counterclockwise) to adjust the internal trim
[number]
until
your voltmeter reads as close to +1.000V as possible, then press the encoder to lock in the
offset.
7.
Patch
OUT B
into your voltmeter, turn the encoder to ‘
OUT B 0V: [number]
’
and repeat Step 4,
then turn the encoder to ‘
OUT B 1V: [number]
’
and repeat Step 6.
8.
Patch
TRK 1 PITCH
into your voltmeter, turn the encoder to ‘
Pitch 1 0V: [number]
’
and repeat
Step 4, then turn the encoder to ‘
Pitch 1 1V: [number]
’
and repeat Step 6.
9.
Patch
TRK 2 PITCH
into your voltmeter, turn the encoder to ‘
Pitch 2 0V: [number]
’
and repeat
Step 4, then turn the encoder to ‘
Pitch 2 1V: [number]
’
and repeat Step 6.
To Save the Calibration:
1.
Turn the encoder to select
‘Save All’
, then press the encoder to save your calibration.
Metropolix Manual