CALIBRATION
Metropolix is calibrated at the factory prior to shipment, so it’s unlikely you’ll ever need to perform
any custom calibration. But if you do, these instructions (along with an external voltage meter) are
all you need to calibrate it.
Entering Calibration Mode
To enter Calibration Mode:
1.
Press the
SETUP
button to open the global SETUP MENU.
2.
Turn the encoder until the
Version
number is highlighted.
3.
Hold down the MOD button while pressing the encoder.
Metropolix enters Factory Mode and displays the
.
4.
Turn the encoder to highlight the
Calibration
option, then press the encoder.
The Calibration Screen appears.
IMPORTANT : DO NOT select any of the other Factory Menu options unless specifically told to do
so by Intellijel Tech Support. If you accidentally select a different Factory Menu item, press the EXIT
button to cancel out of the operation.