background image

1810 NDSU Research Circle N 

Fargo, ND 58102 

www.intelligentag.com 

 

Page 8 of 8

 

Appendix B: 

Motor Controller Harness Connections 

 

Содержание Engage Zone Control

Страница 1: ...ffected Parts PART NAME IAS PART NUMBER IMAGE PROBLEM Engage Zone Control unit 153510 000121 Motor failure Document References The content in this information notice and additional maintenance instructions are found in the Engage Zone Control Maintenance Manual 600840 000047 This document and all other Intelligent Ag support documentation is found at www intelligentag com support About If a motor ...

Страница 2: ...one Control Unit TIP Refer to the diagram in Appendix A for labelled part names 1 Cycle the gates open and closed through the tractor s virtual terminal 2 Unplug the bin harness that plugs into the Engage Zone Control unit enclosure NOTE Be careful not to damage the gasket when removing the lid 3 Clean off any dirt from the enclosure lid Remove the pin from the latches on the sides of the unit and...

Страница 3: ... enclosure The motor controllers must be reinstalled in their original position 6 Use a 15 mm socket ratchet and extension to remove the 2 bolts holding each motor mount to the enclosure Then remove the motor mounts Replacing the Motor 1 Identify the motor that needs to be replaced by referring to the error message on the VT or visually identify the motor that s not moving Then disconnect the powe...

Страница 4: ...turn by hand use a piers to turn the lead screw 3 Using a 5 5 mm socket ratchet and extension remove the four 5 5 mm screws rubber washer and the two stainless steel plates from the face of the motor Then remove the motor from the motor mount If you are submitting a warranty claim keep the motor in case you are asked to submit it with your claim Improper maintenance of the system may void motor wa...

Страница 5: ...re Ensure that the nut holding clips rest on top of the short side of the gates as seen in the diagram in Appendix A and that the magnet is facing up You can move the nut holding clips to align with the gates or pull the gates out to meet the position of the nut holding clips TIP It is easier to align the nut holding clips if you position the motor mount at an angle and align the nut holders indiv...

Страница 6: ... manual NOTE Ensure that that harness is routed toward the back of the enclosure 5 Place the lid back on the enclosure and latch the lid 6 Plug the bin harness into the Engage Zone Control unit enclosure 7 Cycle the gates open and closed through the tractor s virtual terminal Contact Questions Contact Intelligent Ag product support Canadian Product Support 1 306 993 1156 United States Product Supp...

Страница 7: ...1810 NDSU Research Circle N Fargo ND 58102 www intelligentag com Page 7 of 8 Appendix A Engage Zone Control Unit Components ...

Страница 8: ...1810 NDSU Research Circle N Fargo ND 58102 www intelligentag com Page 8 of 8 Appendix B Motor Controller Harness Connections ...

Отзывы: