Intelligent LLEVO-W Скачать руководство пользователя страница 16

 

 

Page

 

15

 

of

 

25

 

 

 

Section

 

3

 

LightLEEDer

 

Wireless

 

Product

 

Installation

 

 

3.0

   

Overview

 

The

 

LightLEEDer

 

Wireless

 

product

 

use

 

a

 

915MHz

 

radio

 

system

 

for

 

communication

 

supporting

 

a

 

50”

 

line

 

of

 

sight

 

distance

 

between

 

devices.

 

When

 

installing

 

always

 

be

 

aware

 

of

 

and

 

avoid

 

other

 

equipment

 

that

 

may

 

produce

 

RF

 

noise

 

that

 

could

 

interfere

 

with

 

the

 

ILC

 

radio

 

communication.

 

Do

 

Not

 

install

 

the

 

devices

 

where

 

a

 

steel

 

structure

 

like

 

ventilation

 

ducts

 

may

 

block

 

or

 

reduce

 

signal

 

strength.

 

Always

 

install

 

the

 

devices

 

in

 

an

 

easy

 

to

 

access

 

location.

 

 

3.1

    

LLEVO

W

 

Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mount

 

the

 

remote

 

LLEVO

W

 

wireless

 

controller

 

in

 

an

 

easy

 

to

 

access

 

location,

  

typically,

 

at

 

the

 

power

 

junction

 

box

 

centrally

 

located

 

to

 

the

 

area

 

to

 

be

 

controlled.

 

 

For

 

best

 

performance

 

always

 

place

 

the

 

LLEVO

W

 

where

 

its

 

radio

 

is

 

not

 

obstructed

 

by

 

metal

 

enclosures

 

or

 

subject

 

to

 

equipment

 

with

 

high

 

EMF

 

noise.

  

 

Verify

 

that

 

the

 

LLEVO

W

 

is

 

within

 

50

 

feet

 

line

 

of

 

sight

 

to

 

all

 

switch

 

stations

 

and

 

relays

 

intended

 

to

 

be

 

linked

 

to

 

the

 

controller.

 

 

Mount

 

the

 

LLEVO

W

 

to

 

the

 

junction

 

box

 

using

 

the

 

1/2"

 

nipple

 

and

 

secure

 

the

 

controller

 

using

 

the

 

1/2"

 

locknut

 

provided

 

and

 

mounting

 

bracket.

 

 

Terminate

 

the

 

line

 

voltage

 

lighting

 

circuit

 

120

 

or

 

277VAC

 

power

 

leads

 

to

 

the

 

controller

 

as

 

required

 

by

 

NEC

 

Code.

  

 

Run

 

CAT

5

 

data

 

cable

 

from

 

the

 

ILC

 

panel

 

network

 

to

 

the

 

LLEVO

W

 

controller

 

In/Out

 

ports

 

to

 

add

 

this

 

controller

 

to

 

the

 

system.

 

 

Set

 

the

 

controller's

 

unique

 

address

 

(2

digit

 

HEX)

 

and

 

record

 

for

 

future

 

reference.

 

 

The

 

LLEVO

W

 

can

 

be

 

programmed

 

for

 

stand

alone

 

or

 

network

 

operation

 

from

  

the

 

ILC

 

network

 

system,

 

refer

 

to

 

LL

Pro

 

software

 

instructions.

 

 

To

 

link

 

the

 

LightLEEDer

 

wireless

 

relays

 

and

 

LightSync

 

G3

 

wireless

 

switches

 

to

 

the

 

LLEVO

W

 

controller

 

refer

 

to

 

TB0402.

 

 

 

Содержание LLEVO-W

Страница 1: ...LightLEEDer Wireless LLEVO W LSG3 W WR5D WR20D and WR20D 2 WR20D EM...

Страница 2: ...Statement This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any int...

Страница 3: ...eatures Section 2 LightLEEDer Wireless Product and Wiring Details 2 0 Overview 2 1 LLEVO W Details 2 2 WR5D WR20D WR20D 2 Details 2 2 1 WR5D Details 2 2 2 WR20D and WR20D 2 Details 2 3 WR20D EM Detail...

Страница 4: ...nk a WR20D 2 Relay 4 4 1 Link to Load 1 Relay 1 Dimmer 1 4 4 2 Link to Load 2 Relay 2 Dimmer 2 4 5 Clear all Settings in the Relay s Link Memory 4 6 Direct Link Notes Section 5 Wireless EVO Configurat...

Страница 5: ...same control options as a standard wired EVO controller with the enhanced wireless radio connection to inputs and outputs 1 1 1 Features Made in USA 915Mhz radio communication with 50 foot line of si...

Страница 6: ...n one convenient package Relays are available in both a wireless WR20D EM version and a hardwired version R20D EM The WR20D EM communicates with a 915 MHz radio with other ILC wireless devices When no...

Страница 7: ...ade in USA Digital 915Mhz radio communication with 50 foot line of sight range 10 Year lithium battery Direct Link to wireless relays or networked with EVO W controller Unique ID radio transmit code p...

Страница 8: ...Wire the LightLEEDer EVO Wireless controller to 120 or 277VAC power within range of the wireless devices to be controlled Wireless devices are linked to the LLEVO W controller using a 915Mhz radio sig...

Страница 9: ...e relay LED status should light green for relay on The WR5D can direct link to LSG3 W switches or to the LLEVO W for networking Electrical Operating Environment Wire Color Guide 1 Load with Dimming Lo...

Страница 10: ...Page 9 of 25 2 2 2 WR20D and WR20D 2 Details...

Страница 11: ...to the LLEVO W for networking Electrical Operating Environment 1 or 2 Load Independent with Dimming Location Interior 16Amps 120 277 VAC LED Electronic Operating Temp 0 50 deg C 20Amps 120 277 VAC Tu...

Страница 12: ...witch Fire or security interface The input accepts a two wire non polarized 10 28VDC VAC at 10mA maximum Press the Wireless Link Test button to toggle the relay LED status should light green for relay...

Страница 13: ...tput Blue Dimming 0 10VDC Red Purple Dimming 0 10VDC Purple Dimming 0 10VDC Red Pink Dimming 0 10VDC Pink The WR20D EM Relay combines both normal and emergency powered lighting control in the same dev...

Страница 14: ...s or to the LLEVO W for networking Caution The WR20D EM devices are feed from two independent electrical circuits When servicing confirm that both circuit breakers are switched OFF to prevent accident...

Страница 15: ...set Location Interior Wireless 915Mhz communication Operating Temp 0 50 deg C Lithium battery provided CR123A Humidity 10 90 Non Condensing Mounting screws provided Atmosphere Non Explosive Corrosive...

Страница 16: ...LLEVO W where its radio is not obstructed by metal enclosures or subject to equipment with high EMF noise Verify that the LLEVO W is within 50 feet line of sight to all switch stations and relays int...

Страница 17: ...the fixture or line voltage junction box using the 1 2 nipple and secure the relay using the 1 2 locknut provided Terminate the line voltage 120 277VAC power neutral and fixture load output leads from...

Страница 18: ...and mounting bracket Terminate the line voltage 120 277VAC power neutral and fixture load output leads from the relay to the load wires as required by NEC Code cap off the unused leads If using the W...

Страница 19: ...n box or fixture using the 1 2 nipple and secure with the 1 2 locknut provided and mounting bracket Terminate the Emergency and Normal power line inputs 120 277VAC neutrals and fixture control load ou...

Страница 20: ...g brackets are recommended if allowed by code along with a plastic cover plate Mount LSG3 W switch in standard 1 gang switch bracket or junction box using screws provided Verify that the switch statio...

Страница 21: ...link the switch to the relay or relays to be controlled 4 If the relay and switch have previously been linked you will need to clear the link settings in the relay s memory before proceeding See sect...

Страница 22: ...e LSG3 W switch for desired Zone 2 control Relay 2 will turn OFF and ON to indicate the link was accepted 3 Press the button on additional LSG3 W switches for Relay 2 Dimmer 2 if needed 4 Press the li...

Страница 23: ...ink button to toggle the relay On Off 3 Record the relays unique ID 8 digit code for reference during programming 4 Install the LSG3 W wireless switch with the provided battery 5 Record the switch s u...

Страница 24: ...s Link page in the LightLEEDer Pro software will display all 64 possible LS switch addresses and relay dimmer outputs It also has buttons at the bottom of the page for Get Links and Send Links to the...

Страница 25: ...e my switch is a LSG3 W 2MZD with an ID 04 CE 86 C4 The LLEVO W also received a relay dimmer at ID 03 24 EE 15 The LLEVO W panel will always display the last device ID it received within its radio ran...

Страница 26: ...o a LLEVO W panel that has existing Links configured use the Get Links from EVO button to retrieve the current Link data into the software To Add a wireless photocell sensor or wireless occupancy sens...