Power Path Module Data

PPM Data

6

6

6.1

6.2

6.2.1

6.2.2

Output UART data format

The communication port has a serial format. The parameters are as follows:

UART: 

9600 baud, 8 data bits, 1 stop bit, and no parity

Format: 

There are 14 messages in the data stream

A typical message from the UART will be formatted as follows:

<6708,85.0,75.0,2,00000000,85.0,78.0,2,00000000,85.0,1800.0,45.00,40.00,249>

SD card data

The SD card contains data from the operation of the fuel cells.

SD card data designation

On the SD card there will be a folder called 

Data

 containing .csv files with the 

columns having the following headings:

Power Path Module fault codes

The fault codes for the PPM as stored in the PPM SD card are shown below. 
For fault codes from the FCPM SD card refer to the FCPM User Manual.

The naming of the unit is covered in N type rows. Serial number will be displayed as 
a 15 digit alpha numeric. The software version will be displayed in the format X.XX. 

Data title

Units

Description

Time

Secs

Time from when PPM 
powered on

FCPM #1 Tank Pressure 

%

0 to 100 (5Bar to 300Bar)

FCPM #1 Battery Level

%

0 to 100 (19.6V to 24V)

FCPM #1 State

N/A

0 to 8

FCPM #1 Fault Codes

N/A

00000000 to 80000000

FCPM #2 Tank Pressure 

%

0 to 100 (5Bar to 300Bar)

FCPM #2 Battery Level 

%

0 to 100 (19.6V to 24V)

FCPU #2 State

N/A

0 to 8

FCPU #2 Fault Codes

N/A

00000000 to 80000000

Tank Pressure

Bar

0 to 300

Output Power 

Watt

0 to 2800

Output Voltage

Volt

0 to 50

Output Current

Amp

0 to 50

Bit Statuses (5×DI, 1×DO) 

N/A

000000 to 11111

Data title

Units

Description

FCPM #1 Tank Pressure 

%

0 to 100 (5Bar to 300Bar)

FCPM #1 Battery Level

%

0 to 100 (19.6V to 24V)

FCPM #1 State

N/A

0 to 8

FCPM #1 Fault Codes

N/A

00000000 to 80000000

FCPM #2 Tank Pressure 

%

0 to 100 (5Bar to 300Bar)

FCPM #2 Battery Level 

%

0 to 100 (19.6V to 24V)

FCPU #2 State

N/A

0 to 8

FCPU #2 Fault Codes

N/A

00000000 to 80000000

Tank Pressure

Bar

0 to 300

Output Power 

Watt

0 to 2800

Input Voltage

Volt

0 to 50. 
The sum of the output 
voltages for the two FCPMs

Output Current

Amp

0 to 50

Output Voltage

0 to 50 Volt

Output voltage from the 
PPM

5xDI, 1xDO bit statuses

N/A

000000 to 11111

Software Version

N/A

1.00 to 9.99

PPM Serial Number

N/A

15 characters (alphanumeric)

SPPM Fault Code

N/A

00000000 to 80000000

Fault code

Description

Condition

Sustained delay (s)

80000000

The Master Output FET has 
failed short

Master Output not enabled 
and voltage difference across 
the Ideal Diode less than 3V

0.50

40000000

The Master Output FET has 
failed to switch on (allow 
current)

Master Output enabled and 
voltage difference across the 
Ideal Diode greater than 3V

0.50

Содержание Power Path Module

Страница 1: ...Power Path Module User Manual Users must read all instructions provided and retain the manual for future reference Document No 10010369 ...

Страница 2: ...ies and procedures that may apply to the operation of stationary and portable power applications and use and storage of hydrogen on any sites Intelligent Energy warrants to the recipient and it will repair and replace any defective equipment resulting from the authorised use of the equipment provided Notwithstanding the above Intelligent Energy to the fullest extent permitted by law accepts no lia...

Страница 3: ...42A 38 4V 32A 50V Output voltage range 38 4 to 50V FCPM 1 input voltage range 19 6 to 25V FCPM 2 input voltage range 19 6 to 25V Environmental operating conditions Operating temperature range 5 to 35 C Storage temperature 40 to 70 C Fuel Cell Power Module and Power Path Module architecture The PPM allows you to connect two Intelligent Energy UAV Fuel Cell Power Modules FCPM in series to provide a ...

Страница 4: ...s 4 PPM SD card NA All cases 5 Input power connection FCPM 1 FCPM 1 output All cases 6 FCPM 1 UART FCPM 1 UART All cases 7 FCPM 1 pressure FCPM 1 regulator interface If this port is left empty for dual operation port 11 must be used 8 Input power connection FCPM 2 FCPM 2 output All cases 9 Intelligent Energy use only NA NA 10 FCPM 2 UART FCPM 2 UART All cases 11 FCPM 2 pressure FCPM 2 regulator in...

Страница 5: ...FCPM 2 Tank Pressure 0 to 100 5Bar to 300Bar FCPM 2 Battery Level 0 to 100 19 6V to 24V FCPU 2 State N A 0 to 8 FCPU 2 Fault Codes N A 00000000 to 80000000 Tank Pressure Bar 0 to 300 Output Power Watt 0 to 2800 Output Voltage Volt 0 to 50 Output Current Amp 0 to 50 Bit Statuses 5 DI 1 DO N A 000000 to 11111 Data title Units Description FCPM 1 Tank Pressure 0 to 100 5Bar to 300Bar FCPM 1 Battery Le...

Страница 6: ... from a separate cylinder The PPM manages the signals from each and creates one data stream to the UAV Single cylinder configuration In this configuration each FCPM is connected to the same cylinder The PPM manages the signals from each and creates one data stream to the UAV Additionally each diagram has the port for the connection to the PPM labelled Power Cable Hydrogen Feed Regulator Connection...

Страница 7: ...ess 3sec 2 Long Press the start button on FCPM 1 Button press 3sec 3 Disconnect the Hybrid Battery from FCPM 1 4 Disconnect the Hybrid Battery from FCPM 2 Fault conditions If the PPM detects a problem it will indicate it via the LED Troubleshooting Amber LED fault If the Amber LED light is shown check that both FCPMs are operating and the cables are correctly connected Red LED fault If the Red LED...

Страница 8: ... of the Directives set out above and the following standards documents EN 61000 6 2 2005 Electromagnetic compatibility EMC Generic standards Immunity for industrial environments EN 61000 6 4 2007 A1 2011 Electromagnetic compatibility EMC Generic standards Emission standard for industrial environments A copy of the official version of this certificate duly signed by an authorised signatory of the m...

Страница 9: ...being a complete source of Information To the fullest extent permitted by law Intelligent Energy offers no warranty as to the accuracy of the content of this publication shall not be liable for the content of this publication and no element of this publication shall form the basis of any contractual relationship with a third party Printed January 2020 56708 IE UM 202001 Published by Intelligent En...

Отзывы: