![Intelligent Appliance IA-3121-E Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/intelligent-appliance/ia-3121-e/ia-3121-e_user-manual_2073954020.webp)
IA-3121-E
20
Specifications are subject to change without notice
32-ch Solid-State Relay (SSR) Board,
Ethernet IP Controlled
IA Series-3000 Daisy-Chain
!aaBndd – Set Relays Status at Level
Description
This command sets the status of 8 relays at a time.
Syntax
!aaBndd <CR>
!
Delimiter character
aa
Hexadecimal address of the device
B
Change Byte Level command
n
#Byte to be set.
‘n’ is in the range of 0-3
dd
Byte data in hex format.
<CR> Carriage Return - End of command
Response
|n dd<CR> if the command was valid
Example
Command: !00B124<CR>
Response: |1 24<CR>
This command will activate relays #10 and #15(!) all other relays will be not
changed.