32
INS-1500 & INS-2000 • 5403646 • REV F • 04/19
Lubricated Air Compressor Oil:
12.
To clean the self-contained strainer, briefly rotate the black handle 90 degrees to purge any contaminates from strainer.
Fig. 43
Air Tank Blow-Down Strainer Screen:
11. Locate the inline blow-down device mounted on the base of the compressor tank. See Fig. 42.
Fig. 42
13.
Remove oil fill plug.
14. Remove drain cap from oil drain port and drain oil into suitable container.
15. Reinstall drain cap.
16.
Place funnel into oil fill port and add oil (approximately 1.6 qts.) until visible at the top of the oil sight glass.
17.
Replace oil fill plug.
Blow-down strainer
Oil Fill Port
Oil Drain Port
Oil Sight Glass