Socket Mechanical Design
Intel
®
Xeon
®
Phi™ Processor x200 Product Family TMSDG
Order Number: 334785-002
30
.
Figure 3-9. Wetting Angle and Wetting Height
3.4
Socket Size
The socket size will meet the dimensions as shown in
, allowing full insertion
of the package into the socket without interference. This information should be used in
conjunction with the reference main board keep-out drawings provided in
ensure compatibility with the reference thermal mechanical components.
3.5
Actuation and Insertion Requirements
3.5.1
Package Translation
The socket should be built so that the post-actuated seating plane of the package is
flush with the seating plane of the socket. Movement will be along the axis normal to
the seating plane.
3.5.2
Insertion/Removal/Actuation Forces
Any actuation will meet or exceed
SEMI S8-95 Safety Guidelines for
Ergonomics/Human Factors Engineering of Semiconductor Manufacturing Equipment
example Table R2-7 (Maximum Grip Forces), available at
http://www.semi.org/
.
The socket is designed so that no force is required to insert the package into the
socket, and no tool is required to insert or remove the package
.
Table 3-3.
PnP Cover Ergonomics Requirements
Direction
Description
Min.
Max.
Comments
Vertical
Closed position at 260
°
C
0.75 lbf
-
While holding at reflow temp.
Closed position at room
temperature.
3 lbf
22 lbf
Pull off force for cap removal.
In and
Out of
Plane
Shock
0.8 lbf
-
During shipping.
In-Plane
Removal
-
1.7 lbf
Will meet Ergonomic requirements.
PnP Cap
-
-
+/- 3.5 mils placement accuracy; in-plane
slack.