background image

Intel

®

 RAID Controller SRCSATAWB

 

Hardware User’s Guide

Intel Order Number: D92006-001

Содержание SRCSATAWB - RAID Controller

Страница 1: ...Intel RAID Controller SRCSATAWB Hardware User s Guide Intel Order Number D92006 001 ...

Страница 2: ...UCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products are not intended for use in medical life saving life sustaining applications Intel may make changes to specifications and product descriptions at any time without notice Intel is a trademark or registered tra...

Страница 3: ... benefit from this book are Engineers who are designing a Intel RAID Controller SRCSATAWB storage adapter into a system Anyone installing a Intel RAID Controller SRCSATAWB storage adapter in their RAID system Organization This document includes the following chapters and appendixes Chapter 1 provides a general overview of the Intel RAID Controller SRCSATAWB Chapter 2 describes the procedures for i...

Страница 4: ...iv Intel RAID Controller SRCSATAWB Hardware User s Guide ...

Страница 5: ...D Controller 6 Configure the RAID Controller 9 Replacing a Controller Resolving a Config Mismatch 9 Chapter 3 Intel RAID Controller SRCSATAWB Characteristics 10 Technical Specifications 11 Array Performance Features 12 Fault Tolerance 12 Electrical Characteristics 13 Safety Characteristics 13 A Drive Roaming and Drive Migration Install 15 Drive Roaming 15 Drive Migration 16 B Installation Assembly...

Страница 6: ...d cabling smaller connectors lower pin counts and lower power requirements than parallel SCSI The optional Intel RAID Smart Battery AXXRSBBU4 provides cached data protection for the RAID controller even during system failures Intel RAID Controller SRCSATAWB The Intel RAID Controller SRCSATAWB is an intelligent low profile RAID adapter with an integrated LSI 1078 RAID On Chip chipset providing both...

Страница 7: ...ves Support for intelligent XOR RAID levels 0 1 5 6 10 50 and 60 Dedicated or global hot spare with auto rebuild if an array drive fails User defined stripe size per drive 8 16 32 64 def 128 256 512 KB or 1 GB Advanced Array configuration and Management Utilities provides Online Capacity Expansion OCE adds space to existing drive or new drive See Appendix A for limitations on OCE and RAID migratio...

Страница 8: ...mponents Patrol Read checks drives and maps bad sectors Commands are retried at least four times Firmware provides best effort to recognize an error and recover if possible Failures are logged from controller and drive firmware and SMART monitor Failures are logged in NVRAM viewable from OS Event Log Intel RAID Web Console 2 CIM LEDs and via alarm Multiple cache options allow configuration specifi...

Страница 9: ...ps SATA data transfers Scalable interface that supports up to 16 physical devices and 64 logical devices via expanders Supports SSP to enable communication with other SATA devices Supports SMP to communicate topology management information Supports single PHY or wide ports consisting of 2 3 or 4 PHY within one quad port Allows addressing of multiple SATA targets through an expander if using SATA 2...

Страница 10: ... 5 to RAID 0 RAID 6 to RAID 0 With OCE migrations supported are RAID 0 to RAID 1 RAID 0 to RAID 5 RAID 1 to RAID 5 Beep Codes Short beep 1 second on 1 second off Array is degraded but no data lost Long beep 3 seconds on 1 second off Array has failed Data has been lost Short beep 1 second on 3 seconds off Using hot spare in rebuild Alarm will continue during rebuild with a different sound at comple...

Страница 11: ...l the RAID Controller 1 Turn off the power to the system and all drives enclosures and system components Remove the power cord s 2 Follow the instructions that came with your server system to remove the server cover 3 If necessary change the bracket on the RAID controller to fit the height of the server system See the following figure Figure 1 Changing the Bracket 4 Install the RAID controller int...

Страница 12: ...e the cables provided or use the shortest possible cable Do not use cables longer than one meter Decrease the maximum length by one foot if using a backplane Do not use cross over cables The cables are labeled with the word SAS but only SATA drives are supported Do not attempt to install a SAS drive Only connect to a SATA drive or to a SAS SATA backplane The RAID Controller SRCSATAWB uses an advan...

Страница 13: ...TAWB Hardware User s Guide 8 Figure 3 Connecting Cables between the RAID Controller and Drives Backplane 6 Install the server system cover and connect the power cords See your server system documentation for instructions AF002211 ...

Страница 14: ... the Intel RAID Controller SRCSATAWB Quick Start User s Guide and the Software User s Guide for instructions to configure the RAID controller and to install the operating system drivers Replacing a Controller Resolving a Config Mismatch To replace the RAID controller see your server system documentation for instructions to remove and then install an add in adapter If the newly installed RAID contr...

Страница 15: ...ht ports not available through expander J6 I2C header SES2 3 pin header Enclosure management support usually a non expander hot swap backplane J7 Battery connector Daughter card connector Connector used for optional battery backup pack J8 Internal SAS SATA port connector SFF8087 For ports 0 3 J9 Internal SAS SATA port connector SFF8087 For ports 4 7 J10 Firmware recovery jumper 2 pin jumper This j...

Страница 16: ...per port with expanders Physical and virtual drive support 16 drives per controller 32 virtual drives per controller 16 hot spares per controller global and or dedicated Cache 128 MBs DDR2 667 MHz SDRAM optional battery backup Firmware 4 M in reflashable flash ROM Compatible devices 2 5 inch and 3 5 inch SATA 3 0 drives non disk devices including expanders and drives of mixed capacity Cabling Smal...

Страница 17: ...tion OCE and Patrol Read Cache options Write back or Write through Read Ahead Adaptive Read Ahead NonRead Ahead Cache I O or Direct I O Self Monitoring Analysis and Reporting Technology SMART support Detects up to 70 of predictable disk drive failures and monitors the internal performance of all motors heads and drive electronics Optional Battery Backup Intel RAID Smart Battery AXXRSBBU4 cache bac...

Страница 18: ...oard is marked with the supplier name or trademark type and UL flammability rating For the boards installed in a PCI bus slot all voltages are lower than the SELV 42 4 V limit PCI 12 V PCI 3 3 Aux PCI 3 3 V Temperatures Other 1 0 1 81A 30mA 330mA 0C to 40C with battery 0 to 50C without battery Non operating no battery 30C to 80C Airflow 200 LFPM relative humidity non condensing 5 90 With battery 2...

Страница 19: ...Intel RAID Controller SRCSATAWB Hardware User s Guide 14 ...

Страница 20: ...use drive roaming 1 Turn off the power to the system and all drives enclosures and system components Remove the power cord s 2 Follow the instructions that came with your server system to remove the server cover 3 Move the drives to different positions on the backplane to change the targets See your server documentation for instructions to install and remove drives 4 Determine the target requireme...

Страница 21: ...stem and all drives enclosures and system components Remove the power cord s 3 Follow the instructions that came with your server system to remove the server cover 4 Disconnect the cables from the drives to be migrated 5 Remove the hard drives from the first system and install them into the second system See your server documentation for instructions to install and remove drives 6 Connect the data...

Страница 22: ...em from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests on your computer system s cables and that the cables are not located where they can be stepped on or tripped over Do not spill food or liquids on your computer If the computer gets wet consult the documentation that came with it Do not p...

Страница 23: ...nt static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal surface such as the metal around the card slot openings at the back of the computer As you continue to work inside the computer periodically touch an unpainted metal surface to remove any static charge you...

Страница 24: ...connect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 6 Do not operate the system with the chassis covers removed After you have completed the six SAFETY steps above you can remove the sy...

Страница 25: ...lter für Gleichstrom nicht ausgeschaltet Ziehen Sie jedes Wechselstrom Netzkabel aus der Steckdose bzw dem Netzgerät um den Stromanschluß des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus 2 Schalten Sie das Syst...

Страница 26: ...r dem Einschalten installiert werden Ein Betrieb des Systems ohne angebrachte Abdeckung kann Ihrem System oder Teile darin beschädigen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich daß Sie keine Werkzeuge oder Teile im Innern des Systems zurückgelassen haben 2 Überprüfen Sie alle Kabel Zusatzkarten und andere Komponenten auf ordnungsgemäßen Sitz und Installation 3 Bringen Sie die Abd...

Страница 27: ...iez la à la masse du système toute surface métallique non peinte du boîtier 6 Ne faites pas fonctionner le système tandis que le boîtier est ouvert Une fois TOUTES les étapes précédentes accomplies vous pouvez retirer les panneaux du système Procédez comme suit 1 Si un cadenas a été installé sur à l arrière du système déverrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez l...

Страница 28: ...nterruptor activado desactivado en el panel frontal no desconecta la corriente alterna del sistema Para desconectarla deberá desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentación INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos periféri...

Страница 29: ...mpruebe que los cables las placas adicionales y otros componentes se hayan instalado correctamente 3 Incorpore las tapas al chasis mediante los tornillos extraídos anteriormente tensándolos firmemente 4 Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización 5 Conecte todos los cables externos y los cables de alimentación CA al sistema S...

Страница 30: ...del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sistema rimettere sempre le coperture del telaio prima di riaccendere il sistema Operare il sistema senza le coperture al loro proprio posto potrebbe danneggiare i componenti del sistema Per rimettere le cop...

Страница 31: ...liance Class B FCC ICES 003 USA Canada CISPR 22 International EN55022 Europe EN55024 Europe CE EMC Directive 89 336 EEC Europe VCCI Japan AS NZS 3548 Australia New Zealand BSMI CNS13438 Taiwan RRL MIC Notice No 1997 41 EMC 1997 42 EMI Korea Product Regulatory Compliance Markings The RAID Controller Card is marked with the following compliance markings Some marking information may be provided on th...

Страница 32: ...the FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Marking Class B USA EMC Marking Class A Canada CANADA ICES 003 CLASS A CANADA NMB 003 CLASSE A EMC Marking Class B Canada CANADA ICES 003 CLASS B CANAD...

Страница 33: ...vide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause har...

Страница 34: ...tal apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil numŽrique respecte les limites bruits radioŽlectriques applicables aux appareils numŽriques de Classe Aprescrites dans la norme sur le matŽriel brouilleur Appareils NumŽriques NMB 003 ŽdictŽe par le Ministre Canadien des Communictations ...

Отзывы: