67
TP01446
CPU 1
CPU 2
CPU 4
CPU 3
3
Password
Clear
J4A1
Default
Enabled
3
BIOS Write
Protect
J4A2
Default
Enabled
3
BIOS
Recovery
J4A3
Default
Enabled
3
NVRAM
Clear
J4A4
Default
Enabled
A
3
Circuit
Breaker Type
J4J3
Default
100 V
15 A
B
Figure 17. Jumper Locations
1.
Observe the safety precautions, warnings, and cautions described in “
Information”, page
2.
Turn off all peripheral devices connected to the system.
3.
Power down the system and unplug both AC power cords.
4.
Remove the top cover. For instructions, see “
5.
Move the NVRAM Clear jumper at location J4A4 on the main board to cover pins 2 and 3.
6.
Install the top cover. For instructions, see “
7.
Plug in the power cords.
8.
Power on the system.
9.
Wait for the system to boot into the Error Manager and report the NVRAM has been
cleared.
10.
Power down the system and unplug both AC power cords.
11.
Remove the top cover. For instructions, see “
12.
Move the NVRAM Clear jumper at location JAA4 on the main board to cover pins 1 and 2.
13.
Install the top cover. For instructions, see “