background image

Intel®

 

Server System SR1625UR TPS 

Cooling Subsystem 

Revision 1.5 

 

 

 

Intel order number E47487-007 

31 

 

Figure 21. 2.5 inch Drive Blank 

4.5

 

Sata HDD Support 

Due to the rotational velocity and vibration impacts that fans have on hard drives, fan 
redundancy is only supported when using SAS hard drives. Additionally the maximum 
supported temperatures when using SATA drives have been affected as follows: 

 

At 1500 m (5000 ft), the maximum ambient temperature is 30°C. 

 

At 900 m (3000 ft), the maximum ambient temperature is 35°C. 

Содержание SR1625UR - Server System - 0 MB RAM

Страница 1: ...Intel Server System SR1625UR Technical Product Specification Intel order number E47487 007 Revision 1 5 August 2010 Enterprise Platforms and Services Division...

Страница 2: ...tions and product descriptions at any time without notice Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined Intel reserves these fo...

Страница 3: ...Mounting Options 15 3 Power Subsystem 16 3 1 Mechanical Overview 16 3 1 1 DC Output Connection Card Edge 17 3 2 Single Power Supply Module Population 17 3 3 Handle and Retention Mechanism 18 3 4 Hot s...

Страница 4: ...us LED 25 4 Cooling Subsystem 26 4 1 Fan Module 26 4 2 Airflow Support 28 4 2 1 Power Supply Zone 28 4 2 2 PCI Riser Zone 29 4 2 3 CPU Memory 29 4 3 DIMM Blank Population 30 4 4 Drive Bay Population 3...

Страница 5: ...System Status LED 63 9 2 3 Drive Activity LED 63 9 2 4 System Identification LED 64 9 3 External Standard Control Panel Connectors 64 9 4 Internal Standard Control Panel Interconnect 64 10 Intel Local...

Страница 6: ...ower Cord Usage Guidelines 79 13 5 Electromagnetic Compatibility Notices 80 13 5 1 FCC Verification Statement USA 80 13 5 2 ICES 003 Canada 81 13 5 3 Europe CE Declaration of Conformity 81 13 5 4 VCCI...

Страница 7: ...le Enclosure Dimensional Drawing 16 Figure 13 DC Output Connection Card Edge 17 Figure 14 Power Supply Module 1 Location 17 Figure 15 AC Power Cord 21 Figure 16 Fan Module 26 Figure 17 Fan Header Assi...

Страница 8: ...Control Panel Buttons 55 Figure 38 Mini Control Panel LEDs 56 Figure 39 Mini Control Panel PCB 59 Figure 40 Standard Control Panel Assembly Module 60 Figure 41 Standard Control Panel Buttons 60 Figure...

Страница 9: ...oltage Regulation Limits 24 Table 16 Over current Protection Limits 240 VA Protection 24 Table 17 Over voltage Protection OVP Limits 25 Table 18 LED Indicators 25 Table 19 Fan Connector Pin Assingment...

Страница 10: ...ors 58 Table 46 20 pin Mini Control Panel Interconnect 59 Table 47 Standard Contol Button and Intrusion Switch Functions 61 Table 48 Standard Control Panel LED Functions 62 Table 49 SSI Power LED Oper...

Страница 11: ...Intel Server System SR1625UR List of Tables Revision 1 5 Intel order number E47487 007 xi Table 66 POST Error Beep Codes 92 Table 67 Integrated BMC Beep Codes 93...

Страница 12: ...List of Tables Intel Server System SR1625UR TPS xii Revision 1 5 Intel order number E47487 007 This page is intentionally left blank...

Страница 13: ...e See the Reference Documents section at the end of this document for a complete list of available documents The Intel Server System SR1625UR may contain design defects or errors known as errata which...

Страница 14: ...ding blocks are used together the fully integrated system will meet the intended thermal requirements of these components It is the responsibility of the system integrator who chooses not to use Intel...

Страница 15: ...t A connector Two RJ 45 10 100 1000 Mb network connections Four USB 2 0 connectors back One USB 2 0 connector front Internal connections One USB 2x5 pin header which supports two USB 2 0 ports One low...

Страница 16: ...ault DIMM Fault CPU Fault 5V STBY System Status System Identification POST Code Diagnostics Power Supply Up to two 650 W power supply modules Fans Five 40x40x56 mm dual rotor system fans Two 56 mm dua...

Страница 17: ...on rules apply Both processors must be of the same processor family Both processors must have the same front side bus speed Both processors must have the same cache size Processors with different spee...

Страница 18: ...the error condition and responds as follows Adjusts all processor frequencies to lowest common denominator Continues to boot the system successfully If the frequencies for all processors cannot be adj...

Страница 19: ...stem Overview Figure 1 Top Down View Passive System Shown 2 3 System Dimensions Table 3 System Dimensions Height 43 2 mm 1 70 in Width without rails 430 0 mm 16 93 in Width with rails 470 0 mm 18 50 i...

Страница 20: ...Optical Drive Bay K Bridge Board D Power Distribution Board L System Fan Bank E Power Supply Modules M Midplane Board Active version shown F Server Board N Mini Control Panel G Intel I O Expansion Mo...

Страница 21: ...support up to six 2 5 inch drives The slimline peripheral bay is capable of supporting one of the following devices CD ROM DVD or DVD CDR A Slimline Optical Drive Bay B Mini Control Panel C 2 5 inch...

Страница 22: ...tel order number E47487 007 2 6 System Board Overview Figure 4 Intel Server Board S5520UR The following figure shows the board layout of the server board Each connector and major component is identifi...

Страница 23: ...Intel Server System SR1625UR TPS Product Overview Revision 1 5 Intel order number E47487 007 11 Figure 5 Intel Server Board S5520UR Components...

Страница 24: ...cessor 1 DIMM Slots Z SATA RAID 5 Key Header K Processor 2 DIMM Slots AA SGPIO Header L Processor 2 BB SATA Connectors M Fan Header CC I O Module Mezzanine Connector 2 N Fan Header DD I O Module Mezza...

Страница 25: ...AF002833 A POST Code Diagnostic LEDs F CPU 1 DIMM Fault LEDs B System Identification LED G CPU 2 Fan Fault LED C Status LED H Memory 2 Fan Fault LED D Memory 1 Fan Fault LED I CPU 2 DIMM Fault LEDs E...

Страница 26: ...that use either a Mini Control Panel Standard Control Panel or Intel Local Control Panel with LCD support When either the Mini Control Panel or the Standard Control Panel is used light pipes on the ba...

Страница 27: ...to support 19 inches wide by up to 30 inches deep server cabinets The system supports three rack mount options A fixed mount relay rack cabinet mount kit Product Order Code AXXBRACKETS which can be c...

Страница 28: ...maximum of 650 Watts of power This chapter provides technical details on the operation of the power supply module and power subsystem For additional information refer to the Intel Server System SR1625...

Страница 29: ...equires that power supply module 1 be populated The power module 1 slot is located closest to the server board away from the side edge of the system see Figure 14 The non operating slot must have the...

Страница 30: ...t Hot swapping a power supply module is the process of extracting and re inserting a power supply module from an operating power system During this process the output voltages remain within specified...

Страница 31: ...ON Green 5 COM Black 17 COM Black 6 5 VDC Red 18 COM Black 7 COM Black 19 COM Black 8 PWR OK Gray 20 Reserved N C 9 5 VSB Purple 21 5 VDC Red 10 12 V3 Yellow Blue Stripe 22 5 VDC Red 11 12 V3 Yellow B...

Страница 32: ...Molex 44476 1111 or Intel approved equivalent Table 10 P4 Hard Drive Interface Board Power Connector Pin Signal 18 AWG Color Pin Signal 18 AWG Color 1 COM Black 5 12 V4 Yellow White Stripe 2 COM Blac...

Страница 33: ...inlet is rated for 15 A 250 VAC 3 6 2 AC Power Cord Specification Requirements The AC power cord used must meet the minimum specification requirements listed in the following table Table 12 AC Power C...

Страница 34: ...or before above 85 VAC 4 VAC Application of an input voltage below 85 VAC does not cause damage to the power supply or blow a fuse 3 6 5 AC Line Dropout Holdup An AC line dropout is defined to be when...

Страница 35: ...on circuit The power supply is tested as described in EN 61000 3 2 Electromagnetic Compatibility EMC Part 3 Limits Section 2 Limits for harmonic current emissions and meets the harmonic current emissi...

Страница 36: ...ply and the PDB 3 8 1 Over current Protection OCP Each DC DC converter output on the PDB has individual OCP protection circuits The power supply and power distribution board combination PS and PDB shu...

Страница 37: ...ive ambient temperature or excessive loading Two sensing points are placed at hot spots one near the exterior face and the other near the interior face of the module In an OTP condition the PSU shuts...

Страница 38: ...fan In addition to the system fans each installed power supply module provides an additional 56 mm dual rotor fan which pulls air from inside the system and blows it out the back The system utilizes...

Страница 39: ...gement Controller to monitor the status of each fan rotor If a fan fails the remaining fans increase their rotation and attempt to maintain the thermal requirements of the system Each system fan has a...

Страница 40: ...cooling FAN_5 4 2 Airflow Support To control airflow within the system a power supply air duct and CPU air duct are used to isolate and direct airflow to three critical areas or zones the power suppl...

Страница 41: ...ry zone is the area between the PCI riser card of the riser assembly and the right chassis wall The airflow for this zone is generated by system fans 1 2 3 and 4 of the fan module Air is drawn from th...

Страница 42: ...B and C slots must either have a DIMM or a DIMM blank installed You may leave the CPU 2 DIMM slots empty or store extra DIMM blanks in the blue DIMM slots Two CPUs installed All Blue DIMM slots A B1 C...

Страница 43: ...o the rotational velocity and vibration impacts that fans have on hard drives fan redundancy is only supported when using SAS hard drives Additionally the maximum supported temperatures when using SAT...

Страница 44: ...ap backplane to improve cable routing within the system The midplane is the key system board of the system It serves as the primary interface between the server board hot swap backplane and control pa...

Страница 45: ...tor H Fan 3 Connector C Mini DIMM Connector I Fan 1 Connector D Fan 6 Connector J Fan 2 Connector E Fan 5 Connector K RAID Activation Key Connector F Bridge Board Connector L Backplane Connector Figur...

Страница 46: ...GND 30 USB2_ESB_DP 90 USB1_ESB_OC_N 31 USB2_ESB_DN 91 USB0_ESB_OC_N 32 GND 92 GND 33 USB2_ESB_OC_N 93 USB0_ESB_DP 34 NIC1_LINK_LED_N 94 USB0_ESB_DN 35 NIC1_ACT_LED_N 95 GND 36 LED_STATUS_AMBER_R1 96...

Страница 47: ...5 FAN_TACH9 6 GND 6 GND 6 GND 7 GND 7 GND 7 GND 8 FAN_PRSNT1_N 8 FAN_PRSNT3_N 8 FAN_PRSNT5_N 9 LED_FAN1_FAULT 9 LED_FAN3_FAULT 9 LED_FAN5_FAULT 10 LED_FAN1 10 LED_FAN3 10 LED_FAN5 J2B2 FAN_2 J3B1 FAN...

Страница 48: ...6 NC_RESERVEDB16 A17 GND B17 SMB_SAS_EDGE_DAT A18 GND B18 NC_RESERVEDB18 A19 GND B19 SMB_SAS_EDGE_CLK A20 SATA3_TX_P B20 NC_RESERVEDB20 A21 SATA3_TX_N B21 GND A22 GND B22 SATA2_TX_P A23 GND B23 SATA2_...

Страница 49: ...TEMP_SENSOR B22 FP_ID_SW_L A23 LED_NIC2_LINK_N B23 BMC_RST_BTN_N A24 LED_NIC2_ACT_N B24 FP_PWR_BTN_N A25 GND B25 FP_NMI_BTN_N A26 V_BLUE_CONN_FP B26 FP_PWR_LED_3VSB A27 V_GREEN_CONN_FP B27 FP_PWR_LED_...

Страница 50: ...D 7 GND J5A1 SAS_8 J6A2 SAS_5 J5B2 SAS_3 J6B2 SAS_1 Pin Signal Name Pin Signal Name Pin Signal Name Pin Signal Name 1 GND 1 GND 1 GND 1 GND 2 SATA_ADDIN2_TX_P 2 SATA4_TX_P 2 SATA2_TX_P 2 SATA0_TX_P 3...

Страница 51: ...uted from the midplane board which plugs directly into the backplane A Slimline Optical Device Connector C SAS SATA hot swap Connectors B Mini Control Panel Connector Figure 25 Hot Swap SAS SATA Backp...

Страница 52: ...P1 N C P2 P5V P3 P5V P4 N C P5 GND P6 GND Table 32 I 2 C Connector Pin Signal Description 1 SMB_VSC_12C_DAT0 2 GROUND 3 SMB_VSC_12C_CLK0 4 Not Used Table 33 PCI Express x4 Slot Connector from Midplane...

Страница 53: ...R_L A32 Ground B32 FP_FLT_LED_5VSB Table 34 PCI Express x4 Slot Connector from Midplane Pin Signal Name Pin Signal Name A1 RST_PWRGD_PS B1 Ground A2 Ground B2 SAS0_RX_DN A3 Ground B3 SAS0_RX_DP A4 SAS...

Страница 54: ...RTS2_L 16 SP_CTS2_L 17 SP_SIN2 18 SP_SOUT2 19 SP_DSR2_L 20 SP_IN_USE 21 FP_NMI_BTN_L 22 GND 23 LED_NIC1_ACT_L 24 LED_NIC1_LINK_R_L 25 Not Used 26 FP_CHASSIS_INTRU 27 FP_ID_SW_L 28 SMB_PB1_5VSB_CLK 29...

Страница 55: ...on SI Ground S2 SAS _TX_DP 0 7 S3 SAS _TX_DN 0 7 S4 Ground S5 SAS _RX_DN 0 7 S6 SAS _RX_DP 0 7 S7 Ground S8 Not Used S9 Not Used S10 Not Used S11 Not Used S12 Not Used S13 Not Used S14 Not Used P1 Not...

Страница 56: ...com default aspx The optical drive type is mounted to a tool less assembly latch that allows for easy installation and fixation in the system Once it is inserted into the system the assembly locks int...

Страница 57: ...Intel Server System SR1625UR TPS Peripheral Drive Support Revision 1 5 Intel order number E47487 007 45 Pin Signal Name KEY P1 N C P2 P5V P3 P5V P4 N C P5 GND P6 GND...

Страница 58: ...Drives Front View 7 1 Hard Drive Bays The system can be configured to support up to eight hot swap 2 5 inch SAS or SATA hard disk drives The hard drives are mounted to hot swap drive trays for easy in...

Страница 59: ...midplane is the key system board of the system It serves as a primary interface between the server board hot swap backplane and control panel Two midplanes are offered for this system a passive SATA S...

Страница 60: ...is used to provide SAS SAS RAID support It has an integrated LSI LSLSAS1078 3 Gb s RAID On a Chip ROC device It provides support for up to eight SAS drives in this system By default this midplane opti...

Страница 61: ...Battery Backup Unit Connector G Fan 4 Connector B Power Connector H Fan 3 Connector C Mini DIMM Connector I Fan 1 Connector D Fan 6 Connector J Fan 2 Connector E Fan 5 Connector K RAID Activation Key...

Страница 62: ...sion and reception rates of up to 10 GB s over a x4 link 7 2 2 4 Optional Hardware RAID Support The active midplane supports options to provide full hardware RAID support Options required to enable ha...

Страница 63: ...kup unit to the midplane 7 3 Hot Swap SAS SATA Backplane The system supports a multifunctional SAS SATA backplane supporting the following features Vitesse VSC410 enclosure management controller o Ext...

Страница 64: ...SAS SATA Backplane Front Side View A USB Connector C Card Edge Connectors to Midplane B Power Connector D 10 pin Control Panel Connector Figure 34 Hot Swap SAS SATA Backplane Back Side View Note Make...

Страница 65: ...n and FRU data 2 I 2 C bus 1 is connected to an LM75 temperature sensor 3 I 2 C bus 2 is connected to an IPMB bus from the server board 4 I 2 C bus 3 is connected to the LSISAS1078 SAS controller 7 3...

Страница 66: ...ation is outlined in the following table Table 41 Hard Drive Activity LED Functionality Condition Drive Type Behavior Power on with no drive activity SAS Ready LED stays on SATA Ready LED stays off Po...

Страница 67: ...is modular in design and supports several push buttons and status LEDs along with one USB port within a very compact design The control panel assembly slides into a slot on the front of the system and...

Страница 68: ...ntrol Panel LEDs The following table identifies each LED and describes their functionality Table 43 Mini Control Panel LED Functions Reference LED Color State Description A System Identification Blue...

Страница 69: ...alled Correctable errors over a threshold of ten and migrating to a spare DIMM memory sparing This indicates that the user no longer has spare DIMMs indicating a redundancy lost condition The correspo...

Страница 70: ...one of the following mechanisms By pressing the System ID Button on the system control panel the ID LED displays a solid blue color until the button is pressed again By issuing the appropriate hex IP...

Страница 71: ...ni Control Panel Interconnect Pin Signal Name Pin Signal Name 1 FP_PWR_LED_R_L 2 FP_PWR_BTN_L 3 FP_SYS_FLT_LED1_R_L 4 FAULT_LED_5VSB 5 FP_SYS_FLT_LED2_R_L 6 FP_NMI_BTN_L 7 P5V_STBY_PWRLED_ANODE 8 GND...

Страница 72: ...dard control panel allows up to six 2 5 inch hard drives to be installed in the system The standard control panel assembly comes pre assembled and is modular in design The control panel assembly modul...

Страница 73: ...and allows for easy identification and location when working from behind a rack of servers C Reset Button Reboots and initializes the system D NMI Button Pressing the recessed button with a paper clip...

Страница 74: ...ication is maintained on standby by the chipset If the system is powered down without going through the BIOS the LED state that is in effect at the time of power off is restored when the system is pow...

Страница 75: ...of them fails Fan alarm Fan failure Number of operational fans should be more than the minimum number needed to cool the system Non critical threshold crossed Temperature and voltage Amber Blink Non c...

Страница 76: ...Table 52 External USB Connectors Pin Description 1 PWR_FP_USB2 2 USB_DN2_FP_R 3 USB_DP2_FP_R 4 GND 5 GND 6 GND 7 GND Table 53 Video Connector Description Pin Pin Description VGA_RED 1 9 GND VGA_GREEN...

Страница 77: ...9 SP_DSR2_L 20 SP_IN_USE 21 FP_NMI_BTN_L 22 GND 23 LED_NIC1_ACT_L 24 LED_NIC1_LINK_R_L 25 Not Used 26 FP_CHASSIS_INTRU 27 FP_ID_SW_L 28 SMB_PB1_5VSB_CLK 29 GND 30 SMB_PB1_5VSB_DAT 31 RST_FP_BTN_L 32 L...

Страница 78: ...for use with or without an outer front bezel Using the Intel Local Control Panel allows up to six 2 5 inch hard drives to be installed in the system Figure 44 Intel Local Control Panel Assembly Modul...

Страница 79: ...S1 4 The power LED sleep indication is maintained on standby by the chipset If the system is powered down without going through the BIOS the LED state that is in effect at the time of power off is res...

Страница 80: ...of operational fans should be more than the minimum number needed to cool the system Non critical threshold crossed temperature and voltage Amber Blink Non critical Non fatal alarm system is likely to...

Страница 81: ...ched using a small 50 pin flat cable USB signals from the card edge connector are routed to the Intel Local Control Panel interface board through matching 10 pin connectors on the interposer board and...

Страница 82: ...Intel order number E47487 007 Table 60 10 pin Control Panel USB Connector Pin Signal Description 1 P5V_USB_P1 2 USB_P1N 3 USB_P1P 4 GND 5 GND 6 P5V_USB_P2 7 USB_P2N 8 USB_P2P 9 GND 10 GND Table 61 Int...

Страница 83: ...eight PCI Express add in card When re inserting the riser assembly into the system tabs on the back of the assembly should be aligned with slots on the back edge of the system The tabs fit into the sl...

Страница 84: ...e 2 g peak 11 milliseconds ESD 15 KV except I O port 8 KV per Intel Environmental test specification System Cooling Requirement in BTU Hr 2550 BTU hour Operating Temperature 10 C to 35 C with the maxi...

Страница 85: ...by the equipment manufacturer Discard used batteries according to manufacturer s instructions ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig h ndtering Udskiftning m kun ske med batteri af samm...

Страница 86: ...end system product may require additional EMC compliance testing For more information please contact your local Intel Representative This is an FCC Class A device Integration of it into a Class B cha...

Страница 87: ...on Data Sheet is available for Intel products For more reference on material restrictions and compliance you can view Intel s Environmental Product Content Specification at http supplier intel com ehs...

Страница 88: ...ental Friendly Use Period Packaging Product Recycling Marks 13 2 Product Regulatory Compliance Markings This Intel Server Chassis product if provided with the following regulatory and safety markings...

Страница 89: ...na China Recycling Mark China Recycling Marks International Battery Perchlorate Warning Information California Perchlorate Material Special handling may apply See www dtsc ca gov hazardouswaste perchl...

Страница 90: ...in your server Ventilation The equipment rack must provide sufficient airflow to the front of the server to maintain proper cooling The rack must also include ventilation sufficient to exhaust a maxi...

Страница 91: ...e earth ground stud s on the rear of the server The safety ground conductor should be connected to the chassis stud with a Listed closed two hole crimp terminal having 5 8 inch pitch The nuts on the c...

Страница 92: ...radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference...

Страница 93: ...tal Apparatus ICES 003 of the Canadian Department of Communications 13 5 3 Europe CE Declaration of Conformity This product has been tested in accordance too and complies with the Low Voltage Directiv...

Страница 94: ...dated product information for configurations can be found on the Intel Server Builder Web site at the following URL If you do not have access to Intel s Web address please contact your local Intel rep...

Страница 95: ...is system may cause Intel System Management Software to incorrectly monitor the system fans The CPU air duct air baffle and DIMM Blanks must be used to maintain system thermals To maintain system ther...

Страница 96: ...o two nibbles an upper nibble and a lower nibble The upper nibble bits are represented by Diagnostic LEDs 4 5 6 7 The lower nibble bits are represented by Diagnostics LEDs 0 1 2 and 3 If the bit is se...

Страница 97: ...X O O X X X O Reset Phase 0xB2h O X O O X X O X DIMM Detection Phase 0xB3h O X O O X X O O Clock Initialization Phase 0xB4h O X O O X O X X SPD Data Collection Phase 0xB6h O X O O X O O X Rank Formati...

Страница 98: ...VGA Remote Console 0x78h X O O O O X X X Resetting the console controller 0x79h X O O O O X X O Disabling the console controller 0x7Ah X O O O O X O X Enabling the console controller Keyboard only USB...

Страница 99: ...O X O O O O X Trying to boot device selection E 0xDF O O X O O O O O Trying to boot device selection F Pre EFI Initialization PEI Core 0xE0h O O O X X X X X Started dispatching early initialization mo...

Страница 100: ...O O O O X O X OS has requested the system to reset ResetSystem has been called Pre EFI Initialization Module PEIM Recovery 0x30h X X O O X X X X Crisis recovery has been initiated because of a user r...

Страница 101: ...immediate corrective action or choose to continue booting Halt The message is displayed on the Error Manager screen an error is logged to the SEL and the system cannot boot unless the error is resolve...

Страница 102: ...MM_C1 failed Self Test BIST Pause 8529 DIMM_C2 failed Self Test BIST Pause 852A DIMM_C3 failed Self Test BIST Pause 852B DIMM_C4 failed Self Test BIST Pause 852C DIMM_D1 failed Self Test BIST Pause 85...

Страница 103: ...correctable ECC error encountered Pause 85A2 DIMM_A3 Uncorrectable ECC error encountered Pause 85A3 DIMM_A4 Uncorrectable ECC error encountered Pause 85A4 DIMM_B1 Uncorrectable ECC error encountered P...

Страница 104: ...t 0xA500 ATA ATPI ATA bus SMART not supported No Pause 0xA501 ATA ATPI ATA SMART is disabled No Pause 0xA5A0 PCI Express component encountered a PERR error No Pause 0xA5A1 PCI Express component encoun...

Страница 105: ...odes Code Reason for Beep Associated Sensors Supported 1 5 2 1 CPU Empty slot population error Processor slot 1 is not populated CPU Population Error Yes 1 5 4 2 Power fault DC power unexpectedly lost...

Страница 106: ...cant Bit MSB Most Significant Bit MTBF Mean Time Between Failure MTTR Mean Time to Repair NIC Network Interface Card NMI Non maskable Interrupt OTP Over temperature Protection OVP Over voltage Protect...