Intel® Server Board SE7520JR2
Introduction
Revision 7.0
3
Adapter Compatibility
: Adapter compatibility validation (CV) testing uses test suites to gain an
accurate view of how the server performs with a wide variety of adapters under the primary
supported operating systems. These tests are designed to show hardware compatibility
between the add-in cards and the server platform and include functional testing only. No heavy
stressing of the systems or the cards is performed for CV testing.
Stress Testing
: This test sequence uses configurations that include add-in adapters in all
available PCI slots for a minimum 72-hour test run without injecting errors. Each configuration
passes an installation test, a Network/Disk Stress test, and tape backup test. Any fatal errors
that occur will require a complete test restart.
1.1.2.1
Support Commitment for Adapter / Peripheral Compatibility and Stress
Testing
Intel commits to provide the following level of customer support for operating systems that
receive Adapter / Peripheral Compatibility and Stress testing:
•
Intel will provide support for customer issues with these operating systems involving
installation and/or functionality of the server board with or without the adapters and
peripherals listed in this document as having been tested under the particular operating
system.
•
Support is defined as assistance in root causing issues, and determining a customer
acceptable resolution to the issue associated with the operating system. The resolution
may include, but is not limited to, on-board controller driver changes, engaging the
vendor for resolution, BIOS changes, firmware changes, or determining a customer
acceptable workaround for the issue.
•
Intel will provide and test operating system drivers for each onboard video, network, and
storage controller.
•
Intel will enable vendors to provide driver support for add-in adapters using these
operating systems.
•
Intel will go through some of the steps to achieve certification to ensure its customers do
not run across any problems, but the actual certification is the responsibility of the
individual customer.
For operating systems, adapter cards, and peripherals not listed in this
document, there is no support commitment. Intel will consider support requests
on a case-by-case basis.
1.2 Pass/Fail Test Criteria
For each operating system, adapter, and peripheral configuration, a test passes if specific
criteria are met. Specific configurations may have had particular characteristics that were
addressed on a case-by-case basis. In general, a configuration passes testing if the following
conditions are met:
•
The operating system installed without error.
-
Manufacturer’s installation instructions or Intel’s best-known methods were used for
the operating system installation.
-
No extraordinary workarounds were required during the operating system
installation.
-
The server system behaved as expected during and after the operating system
installation.