Intel Server Board SE7501BR2 Installation and Integration Guide
Chassis Preparation and Server Board Installation
About the I/O Shield
An ATX 2.03-compliant I/O shield is provided with your server board. The shield is required
by Electromagnetic Interference (EMI) regulations. It minimizes EMI and helps obtain proper
cooling of the server.
The shield fits the rectangular opening near the power supply in the back of the chassis. The
shield has cutouts that match the external I/O connectors (such as keyboard and mouse).
Attaching the Gasket to the I/O Shield
1.
Remove the two backing strips from the gasket.
2.
Press the gasket onto the inside face of the I/O shield as
shown.
Attaching the Label to the I/O Shield
1.
Remove the backing from the label included with your server
board.
2.
Press the label onto the outside face of the I/O shield (A).
Installing the I/O Shield
Position one edge of the shield so that the dotted
groove is outside the chassis wall, and the lip of the
shield rests on the inner chassis wall.
9