
Error Reporting and Handling
Intel® Server Boards SE7320SP2 and SE7525GP2
Revision
4.0
140
6.3.8
Memory Error Codes
Table 70. Memory Error Codes
Tpoint
Description
001h MEM_ERR_CHANNEL_B_OFF
(DIMM mismatch forced Channel B disabled)
002h MEM_ERR_CK_PAIR_OFF
(Slow DIMM(s) forced clock pair disabled)
0E1h MEM_ERR_NO_DEVICE
(No memory installed)
0E2h MEM_ERR_TYPE_MISMATCH
0E3h MEM_ERR_UNSUPPORTED_DIMM
(Unsupported DIMM type)
0E4h MEM_ERR_CHL_MISMATCH
0E5h MEM_ERR_SIZE_MISMATCH
0E6h MEM_ERR_ECC_MISMATCH
0E8h MEM_ERR_ROW_ADDR_BITS
0E9h MEM_ERR_INTERNAL_BANKS
0EAh MEM_ERR_TIMING
0EBh MEM_ERR_INST_ORDER_ERR
0ECh MEM_ERR_NONREG_MIX
0EDh MEM_ERR_LATENCY
0EEh MEM_ERR_NOT_SUPPORTED
0EFh MEM_ERR_CONFIG_NOT_SUPPORTED
0F0h SYS_FREQ_ERR
(Flag for Unsupported System Bus Freq)
0F1h DIMM_ERR_CFG_MIX
(Usupported DIMM mix)
0F2h DQS_FAILURE
(indicates DQS failure)
0F3h MEM_ERR_MEM_TEST_FAILURE
(Error code for unsuccessful Memory Test)
0F4h MEM_ERR_ECC_INIT_FAILURE
(Error code for unsuccessful ECC and Memory Initialization)
6.4 Intel
®
Light-Guided Diagnostics
The server board provides system fault/status LEDs in many areas of the board to alert users to
a particular failure or status of a component on the board. There are fault LEDs for the memory
DIMMs and processors, and status LEDs for 5-volt stand-by and system state.
Содержание SE7320SP2 - 800MHZ Ecc Ddr Xeon
Страница 182: ......