![Intel SBCEFCSW Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/intel/sbcefcsw/sbcefcsw_installation-manual_2072037027.webp)
13
8.
Ensure that the release lever and latch on the switch module is in the open position (perpendicular to the
module).
Figure 4 shows how to install a switch module in the rear of the SBCE unit.
Figure 4. Installing a switch module
9.
Slide the switch module into the switch-module bay until it stops.
10. Push the release lever and latch on the front of the switch module to the closed position.
✏
NOTE
The switch module takes approximately 85 seconds to complete the POST. When the switch
module is powered on, a LED test occurs. All LEDs are lit and remain lit for approximately 10 to
15 seconds and then return to normal state.
11. Make sure that the LEDs on the switch module indicate that it is operating properly. Verify that:
•
When the POST starts, the OK LED on the switch module will be off. The POST tests the condition
of firmware, memories, data paths, and switch logic and uses the heartbeat LED to indicate pass or
fail conditions.
•
The green OK LED on the switch module is lit to indicate that the switch logic has completed POST.
•
The green heartbeat LED on the switch module has a steady flash rate of once per second. This
indicates that the switch module is operating with no errors.
✏
NOTE
If the heartbeat LED is not flashing once per second, the POST has failed. Be sure the SBCE unit is
powered on and the SBCE LEDs are lit. If POST has failed, see the Fibre Channel Switch
Management User’s Guide for diagnostic information.
12. If you have a second switch module to install, repeat Step 5 through Step
; otherwise, go to Step
13. If needed, connect an SFP module option into external Fibre Channel port 1 and Fibre Channel port 2. For
SFP module installation instructions, see the documentation that comes with your SFP module.
✏
NOTE
SFP module options do not come with the switch module but are required to use external switch
module ports.
14.
Use
LC-LC fiber-optic cables to connect the switch module external ports to external Fibre Channel
devices. For more information, see the documentation that comes with your cable options.
✏
NOTE
You can remove and replace an SFP module while the switch module is operating without
damaging the switch module or the SFP module. However, transmission on the affected port will be
interrupted until the SFP module and cables are installed. See the documentation that comes with
your connected Fibre Channel device for information about installation, configuration, and startup
sequence.
Содержание SBCEFCSW
Страница 4: ...iv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 14: ...xiv Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 22: ...8 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 30: ...16 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 34: ...20 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 56: ...42 Intel Server Switch Module SBCEFCSW Installation Guide...
Страница 58: ...44 Intel Server Switch Module SBCEFCSW Installation Guide...