Intel® Server Board S2600CW Family TPS
Appendix C: BMC Sensor Tables
Revision 2.4
153
Appendix C: BMC Sensor Tables
This appendix lists the sensor identification numbers and information about the sensor type,
name, supported thresholds, assertion and de-assertion information, and a brief description
of the sensor purpose. See the
Intelligent Platform Management Interface Specification,
Version 2.0
for sensor and event/reading-type table information.
Sensor Type Codes
Sensor table given below lists the sensor identification numbers and information regarding
the sensor type, name, supported thresholds, assertion and de-assertion information, and a
brief description of the sensor purpose. Refer to the
Intelligent Platform Management
Interface Specification, Version 2.0
for sensor and event/reading-type table information.
Sensor Type
The sensor type references the values in the Sensor Type Codes table in the
Intelligent
Platform Management Interface Specification Second Generation, Version 2.0
. It
provides a context to interpret the sensor.
Event/Reading Type
The event/reading type references values from the Event/Reading Type Code Ranges
and the Generic Event/Reading Type Code tables in the
Intelligent Platform
Management Interface Specification Second Generation, Version 2.0
. Digital sensors are
specific type of discrete sensors that only have two states.
Event Thresholds/Triggers
The following event thresholds are supported for threshold type sensors:
-
[u,l][nr,c,nc]
upper non-recoverable, upper critical, upper non-critical, lower
non-recoverable, lower critical, lower non-critical uc, lc upper critical, lower critical
Event triggers are supported event-generating offsets for discrete type sensors. The
offsets can be found in the Generic Event/Reading Type Code or Sensor Type Code
tables in the
Intelligent Platform Management Interface Specification Second
Generation, Version 2.0
, depending on whether the sensor event/reading type is
generic or a sensor-specific response.
Assertion/Deassertion
Assertion and de-assertion indicators reveal the type of events this sensor generates:
-
As: Assertion
-
De: De-assertion
Readable Value/Offsets
Readable value indicates the type of value returned for threshold and other non-
discrete type sensors.
Readable offsets indicate the offsets for discrete sensors that are readable by means of
the
Get Sensor Reading
command. Unless otherwise indicated, event triggers are
Содержание S2600CW
Страница 9: ...Intel Server Board S2600CW Family TPS Table of Contents Revision 2 4 ix ...
Страница 14: ...List of Tables Intel Server Board S2600CW Family TPS Revision 2 4 xiv This page intentionally left blank ...
Страница 108: ...Intel Server Board S2600CW Platform Management Intel Server Board S2600CW Family TPS 94 Revision 2 4 ...
Страница 184: ...Appendix C BMC Sensor Tables Intel Server Board S2600CW Family TPS 170 Revision 2 4 ...