Intel® Server Board S2600CW Family TPS
Power Supply Specification Guidelines
Revision 2.4
135
10.2.7
Thermal CLST
The power supply shall assert the SMBAlert signal when a temperature sensor crosses a
warning threshold. Refer to the
Intel
®
Common Hardware and Firmware Requirements for CRPS
Power Supplier
for detailed requirements.
10.2.8
Power Supply Diagnostic “Black Box”
The power supply saves the latest PMBus* data and other pertinent data into nonvolatile
memory when a critical event shuts down the power supply. This data is accessible by the
SMBus* interface with an external source providing power to the 12Vstby output.
Refer to the
Intel
®
Common Hardware and Firmware Requirements for CRPS Power Supplier
for
detailed requirements.
10.2.9
Firmware Uploader
The power supply has the capability to update its firmware by the PMBus* interface while it is
in standby mode. This FW can be updated when in the system and in standby mode and
outside the system with power applied to the 12Vstby pins.
Refer to the
Intel
®
Common Hardware and Firmware Requirements for CRPS Power Supplier
for
detailed requirements.
Содержание S2600CW
Страница 9: ...Intel Server Board S2600CW Family TPS Table of Contents Revision 2 4 ix ...
Страница 14: ...List of Tables Intel Server Board S2600CW Family TPS Revision 2 4 xiv This page intentionally left blank ...
Страница 108: ...Intel Server Board S2600CW Platform Management Intel Server Board S2600CW Family TPS 94 Revision 2 4 ...
Страница 184: ...Appendix C BMC Sensor Tables Intel Server Board S2600CW Family TPS 170 Revision 2 4 ...