Intel® RAID Expander Card RES3FV288 Hardware User’s Guide
17
Appendix B:
Technical Specifications
Environmental Specifications
Note:
Your RAID Expander requires adequate airflow to operate reliably. The recommended airflow is 200 LFM
(linear feet per minute), minimum to avoid operating above the maximum ambient temperature. Forced airflow is
required.
The thermal and atmospheric characteristics are:
Ambient temperature with forced airflow
0
°
C to 55
°
C
Relative humidity
20% to 80%, non-condensing
Altitude
Up to 3,000 meters
The storage and transit environment conditions are:
Ambient temperature with forced airflow
-30
°
C to 80
°
C (dry bulb)
Relative humidity
5% to 90%, non-condensing
Mean Operating Time Between Failures number (MTBF):
electrical components
TBD hours at 40
°
C
Note: Ambient temperature is measured 1” from the expander processor.
DC Power Requirements
Bus Type
Description
Requirements
PCIe
Ripple and noise
RAID Expander
12V: TBD mV peak-to-peak (max)
Current Requirements
Product
Typical Current
RAID Expander RES3FV288
All power is supplied to the RES3FV288 French Valley
RAID Expander Card through the standard PCI Express
connector’s 12 V rails, or a remote RA 4-pin 12V power
connector. The +12 V rail is used to generate the other
required voltage rails of 3.3V, 1.8V, 1.005V, and 0.925V
and +1.8 V.
The max operation power is TBD W.