background image

Intel

®

 RAID Expander Card 

RES2SV240 Hardware User’s Guide

Intel Order Number: E93121-003

Содержание RES2SV240

Страница 1: ...Intel RAID Expander Card RES2SV240 Hardware User s Guide Intel Order Number E93121 003...

Страница 2: ...L PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products ar...

Страница 3: ...ho are designing an Intel RAID Expander Card RES2SV240 for their RAID system Anyone installing an Intel RAID Expander Card RES2SV240 in their RAID system Organization This document includes the follow...

Страница 4: ...iv Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 5: ...figuring the Expander Card 9 Replacing the Expander Card 9 Intel RAID Expander Card RES2SV240 Characteristics 11 Major Components 13 LSI LSISAS2x24 24 Port SAS SATA Expander chip 13 Flash ROM 14 Diagn...

Страница 6: ...vi Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 7: ...Card onto a Customized Chassis Wall 8 Figure 4 Cabling among the Expander Card RAID Module Controller and Drives Backplane 9 Figure 5 Card Layout 11 Figure 6 Hardware Block Diagram 12 Figure 7 Intel R...

Страница 8: ...viii Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 9: ...st of Tables Table 1 Jumper Description 12 Table 2 SFF8087 to SFF8087 Connector Pin out 16 Table 3 SATA Connector to SFF8087 Connector Pin out 18 Table 4 SFF8087 with SGPIO Connector Pin out 20 Table...

Страница 10: ...x Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 11: ...to point device interfaces that use simplified cabling smaller connectors lower pin counts and lower power requirements than parallel SCSI Benefits of SAS and SATA SAS is a serial enterprise level de...

Страница 12: ...l RAID Controller RS2WC080 and RS2WC040 Intel Integrated RAID Module SROMBSASMR Note Additional cable might need to be purchased for some of above adapters to connect Additional Intel RAID Controllers...

Страница 13: ...Supports 8 inputs and 16 outputs configuration Output mini SAS connectors support sideband SGPIO as per SFF 8485 specification Onboard 4 pin SGPIO connector to be used for Intel 6 drive hot swap non e...

Страница 14: ...4 Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 15: ...x provided SAS SATA cables for cable requirements see step 6 in Installing the RAID Module Note Intel Corporation strongly recommends using an uninterruptible power supply UPS Installing the RAID Modu...

Страница 16: ...e bracket 4 Install the expander card into an available server system x4 x8 or x16 PCI Express slot see Figure 2 To locate an appropriate slot and for instructions on installing an add in card see you...

Страница 17: ...Express slot if only the cooling condition can meet the expander card s thermal and atmospheric requirement The expander card can therefore be fastened by removing its bracket and fasten it to a cust...

Страница 18: ...end of the SAS SATA cable to the SAS connectors of the controller see your server workstation board or chassis documentation Make sure the cables are properly connected to the controller Note System...

Страница 19: ...onfiguring the Expander Card After physically installed into a server system the Intel RAID Expander Card RES2SV240 is transparent to users in RAID configurations Refer to the technical specification...

Страница 20: ...10 Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 21: ...Intel RAID Expander Card RES2SV240 Hardware User s Guide 11 3 Intel RAID Expander Card RES2SV240 Characteristics Figure 5 Card Layout AF003493 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10...

Страница 22: ...x12 headers can support 24 LEDs J9 SGPIO connector 4 pin connector SGPIO out of band enclosure management specifically to be used for Intel 6 drive hot swap non expander SATA SAS backplane J10 Power c...

Страница 23: ...mbined into wide port s Any phy can be SAS or SATA attached Supports multiple data rates and auto negotiation between the following 1 5Gb s 3 0Gb s and 6 0Gb s SAS 1 5Gb s 3 0Gb s and 6 0Gb s SATA Sup...

Страница 24: ...gnals that can be used as GPIOs Provides LEDs that support drive activity fault and status indications Provides debug capability via either EPP Serial or direct 8 bit CPU interface Provides external m...

Страница 25: ...at pin 1 These pin outs for the serial ATA connector are not compatible with the legacy PATA connector Each SFF8087 connector on this expander card can be used as input or output connector Input means...

Страница 26: ..._C_DN 1 A7 GND B7 GND A8 SAS_A_SB_BP_TYPE B8 SAS_A_SB0 A9 GND B9 SAS_A_SB1 A10 SAS_A_SB4 B10 GND A11 SAS_A_SB5 B11 SAS_A_SB_CTRL_TYP E A12 GND B12 GND A13 SAS_RX_C_DP 2 B13 SAS_TX_C_DP 2 A14 SAS_RX_C_...

Страница 27: ...ernal Cable with one SGPIO Connector Check the RAID controller module and server backplane configuration details from http www intel com support motherboards server in order to get more details of whe...

Страница 28: ...4 GND B4 GND P0_5 RX B3 SAS_TX_C_DN 3 P0_6 RX B2 SAS_TX_C_DP 3 P0_7 GND B1 GND P1_1 GND A4 GND P1_2 TX A5 SAS_RX_C_DP 2 P1_3 TX A6 SAS_RX_C_DN 2 P1_4 GND A7 GND B7 GND P1_5 RX B6 SAS_TX_C_DN 2 P1_6 RX...

Страница 29: ...Cable B15 GND P2_6 RX B13 SAS_TX_C_DP 1 P2_7 GND B12 GND P3_1 GND A15 GND P3_2 TX A16 SAS_RX_C_DP 0 P3_3 TX A17 SAS_RX_C_DN 0 P3_4 GND A18 GND B18 GND P3_5 RX B17 SAS_TX_C_DN 0 P3_6 RX B16 SAS_TX_C_D...

Страница 30: ...P0_1 GND A4 GND P1_7 GND A5 SAS_RX_C_DP 2 P1_6 SAS_TX_C_DP 1 A6 SAS_RX_C_DN 2 P1_5 SAS_TX_C_DN 1 A7 GND P1_4 GND B5 SAS_TX_C_DP 2 P1_2 SAS_RX_C_DP 1 B6 SAS_TX_C_DN 2 P1_3 SAS_RX_C_DN 1 B7 GND P1_1 GN...

Страница 31: ...SAS_RX_C_DP 0 P3_6 SAS_TX_C_DP 3 A17 SAS_RX_C_DN 0 P3_5 SAS_TX_C_DN 3 A18 GND P3_4 GND B16 SAS_TX_C_DP 0 P3_2 SAS_RX_C_DP 3 B17 SAS_TX_C_DN 0 P3_3 SAS_RX_C_DN 3 B18 GND P3_1 GND Expander Connector Pi...

Страница 32: ...ing voltage 12 V Interface to host PCI Express x4 compliant connector only to provide power for the expander card No other PCI Express signals are used SATA bus speed Upto 6 Gbps per port point to poi...

Страница 33: ...storage and transit environment conditions are Temperature range from 30 C to 80 C dry bulb Relative humidity range 5 to 90 non condensing MTBF electrical components number 300 000 hours at 40 C Safet...

Страница 34: ...24 Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 35: ...protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests on your co...

Страница 36: ...ent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal surf...

Страница 37: ...nnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of...

Страница 38: ...ckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollte sich in d...

Страница 39: ...u vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert werden...

Страница 40: ...ts portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Un...

Страница 41: ...po y ser de f cil acceso INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif rico...

Страница 42: ...y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento el micro...

Страница 43: ...del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sistem...

Страница 44: ...34 Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Страница 45: ...on Product Safety and EMC Compliance This Intel Expander Card has been evaluated for regulatory compliance as an Intel end system and is included as part of the end system certification For informatio...

Страница 46: ...36 Intel RAID Expander Card RES2SV240 Hardware User s Guide...

Отзывы: