Calibrating Device with Custom Calibration Sample Application
33
Figure 4-10 Viewpoint #5
Press enter to capture the image. If successful, the frame counter on the lower right
corner will increase to 5/6 meaning 5 out of 6 images are captured. If it failed, a red
error message will appear and user is directed to retake a viewpoint.
4.3.2.6
Viewpoint #6 – Bottom Looking Up
Folding the tripod so that the device will be in a very low position looking up to the
target. Use the viewpoint below for reference.
Содержание RealSense D400 Series
Страница 1: ...Intel RealSense Depth Module D400 Series Custom Calibration Revision 1 1 0 January 2018 ...
Страница 16: ...Setup 16 Figure 3 4 Tripod ...
Страница 27: ...Calibrating Device with Custom Calibration Sample Application 27 Figure 4 3 Center Right ...
Страница 29: ...Calibrating Device with Custom Calibration Sample Application 29 Figure 4 5 Left Figure 4 6 Viewpoint 3 ...
Страница 32: ...Calibrating Device with Custom Calibration Sample Application 32 Figure 4 9 Top Looking Down ...
Страница 41: ...Calibrating Device with Custom Calibration Sample Application 41 ...
Страница 49: ...Developing Custom Calibration Application 49 ...