Calibrating Device with Custom Calibration Sample Application
31
Figure 4-8 Viewpoint #4
Press enter to capture the image. If successful, the frame counter on the lower right
corner will increase to 4/6 meaning 4 out of 6 images are captured. If it failed, a red
error message will appear and user is directed to retake a viewpoint.
4.3.2.5
Viewpoint #5 – Top Looking Down
Adjust the tripod so the device high enough to look down the target at an angle. Use
the viewpoint below for reference.