Intel® Server System R2600SR Setup and Service Guide
74
Figure 72. Fan cable connection to the PIOR, right
3.
Reconnect the fan cable to the PIOR, right.
3.17.6
After Replacing a PIOR
After replacing a PIOR, complete the following steps to reinstall the shuttle and return the system to service.
1.
Reinstall all the PCIe* add-in cards that were removed (see Section 3.16.5).
2.
Reinstall the EIOM into the shuttle (see Section 3.15.3).
3.
Reinstall the shuttle into the chassis (see Section 3.15.4).
4.
Reconnect the power cords and any cables that were removed.
5.
Reinstall the compute nodes into the chassis (see Section 3.1.2).
6.
Power on all the compute nodes.
3.18
Replacing the Power Distribution Module (PDM)
The Power Distribution Module (PDM) field replaceable unit (FRU) consists of the shuttle sheet metal cage,
four empty PCIe* cassettes, and a printed circuit board mounted under the system fans in the system shuttle
assembly. Replacing the PDM consists of removing all components of the shuttle and returning the PDM
board, empty PCIe cassettes, and shuttle cage.
3.18.1
Preparing to Remove the PDM
Before removing the PDM, perform the following procedure:
1.
Turn off all compute nodes and peripheral devices.
2.
Disengage all compute nodes from the chassis (see Section 3.1.1).
3.
Disconnect the power cords and all external cables from the rear of the chassis.
4.
Remove the shuttle from the chassis (see Section 3.15.1).