Intel® Server System R2600SR Setup and Service Guide
45
3.11.2
Updating Desk Management Interface/System Management BIOS (DMI/SMBIOS) Data
The Desktop Management Interface (DMI) along with the System Management BIOS (SMBIOS) must be
updated when the system board is replaced. Two methods may be used to update the DMI/SMBIOS data.
3.11.2.1
Baseboard Management Controller (BMC) Provisioning Manager
Use the BMC Provisioning Manager to update the asset tag for the system:
1.
Start the system. Press F1 to display the BMC Provisioning Manager System Setup interface.
2.
From the System Summary page, click Update VPD.
3.
Update the asset tag information.
4.
Restart the system.
3.11.2.2
One CLI
OneCLI is an on-line tool that supports a number of various operating systems.
To download OneCLI, complete the following steps:
1.
Download and install OneCLI.
a.
http://downloadcenter.intel.com/
and navigate to the support page for the server.
b.
Click Drivers & Software.
c.
Navigate to the version of OneCLI for the operating system and download the package.
2.
Make sure that the correct version is downloaded for the operating system installed on the system.
3.
Follow the steps below to update UUID using OneCLI. OneCLI sets the UUID in the BMC Controller.
4.
Select one of the following methods to access the BMC Controller and set the UUID:
a.
Online from the target system, such as LAN or keyboard console style (KCS) access
b.
Remote access to the target system (LAN-based)
c.
Bootable medium containing ASU (LAN or KCS, depending upon the bootable media)
5.
Follow the steps below to set the UUID using One CLI.
a.
Copy and unpack the OneCLI package, which also includes other required files, to the solution.
b.
Make sure that to unpack the OneCLI and the required files to the same directory. In addition to
the application executable, the following files are required:
For Windows-based operating systems:
ibm_rndis_server_os.inf
device.cat
For Linux-based operating systems:
cdc_interface.sh
c.
After installing OneCLI, use the following command syntax to set the DMI:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
[access_method] onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum
<s/n> [access_method]
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
[access_method]
where:
<m/t_model>
The solution machine type and model number. Type
mtm xxxxyyy
, where
xxxx
is the machine
type and
yyy
is the solution model number.
Содержание R2600SR Series