Intel® Server System R2600SR Setup and Service Guide
25
3.2
Replacing the Air Baffle
Always operate this server system with the air baffle in place. The air baffle is required for proper airflow
within the server system.
Figure 16. Removing the air baffle
The air baffle is removed for access to the node DIMMs and midplane cables.
1.
Remove the compute node (see Section 3.1.1).
2.
Remove the compute node cover (see Section 3.1.3).
3.
Slightly push in on the release latches located at the left and right ends of the air baffle and attached
to the sides of the node.
4.
Lift the air baffle up and out of the compute node.
3.2.1
Installing the Air Baffle
Reinstall the air baffle when repair or upgrade work is completed in the compute node. The air baffle is
required for proper airflow within the server system.
Figure 17. Installing the air baffle