7.2
Replacing the System Fan
System fans used in the Intel Server System R2000WT product family are hot-swappable.
7.2.1
To remove a failed system fan
•
Remove the system top cover (see section 2.2.1)
•
Squeeze the two loop handles on the top side of the fan, and pull straight up until it clears the fan
assembly bracket
Figure 101. System Fan Installation
7.2.2
To install a new system fan
•
Locate the replacement fan (Intel product Code – FR2UFAN60HSW)
•
Orient the fan so the arrow located on the top side of the fan points to the back of the system
•
Insert the fan into the fan assembly bracket
•
Push down until it is firmly seated into the server board connector
•
Re-install system top cover (see section 2.2.2)