Intel® Server System M50FCP1UR System Integration and Service Guide
90
6.14
Server Board Replacement
Required Tools and Supplies
•
Intel® Server Board M50FCP2SBSTD spare
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver #2
Figure 123. Server Board Removal
1.
Power off system and remove power cords from each power supply module installed.
2.
Disconnect all externally attached cables.
3.
Remove the system top cover (see
Section 6.1.1
4.
Remove power supply modules (see
Section 6.4
5.
Remove all system fans (see
Section 6.2
6.
Disconnect all internal cables attached to PCIe add-in cards.
7.
Remove riser card assemblies (see
Section 6.6