6.7
Front Drive Replacement
The Intel® Server System M50FCP1UR has front drive bays that only support 2.5” SSDs. Supported SSDs can
have a drive height of 7mm or 15mm. 7mm must be attached to a supplied drive mounting bracket to be
compatible with the front drive bays.
All drives are mounted to a tool-less, non-detachable, drive rail. Drives interface with a backplane that is
mounted to the back side of the front drive bay. Data I/O cables are attached between the backplane and
various storage controller options within the system. The front drives are hot swap capable with supported
redundant RAID configurations.
This section provides procedures for the replacement of a faulty SSD.
Required Tools and Supplies
•
Replacement 2.5” Solid State Drive (SSD)
•
Anti-static wrist strap and conductive workbench pad (recommended)
The following figure identifies the 2.5” drive bay components.
Figure 98. Drive Bay Components
Note:
To ensure proper system airflow requirements, all front drive bays must be populated with either a
drive or supplied drive blank.
Note:
The integrated 2.5” drive rails are not removable. They slide out far enough to allow SSDs or drive
blanks to be serviced. When sliding out a drive rail from the drive bay, only pull it as much as it allows
without forcing it.
6.7.1
2.5” SSD Drive Removal
Figure 99. 2.5” 15 mm Drive Removal
Содержание M50FCP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Страница 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Страница 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Страница 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Страница 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Страница 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...