Intel® Server System M50CYP2UR Family System Integration and Service Guide
57
3.5
Ethernet Network Adapter for OCP*
–
Installation / Removal
This section provides instructions for OCP* adapter installation and removal from the chassis.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver #1.
To broaden the standard onboard feature set, the server system supports the Intel® Ethernet Network
adapters indicated in the following table. These adapters are compatible with the Open Compute Project*
(OCP*) 3.0 Specification.
Note:
Only the Ethernet Network Adapters for OCP listed in the following table are supported.
All OCP* adapter types support one of three engagement mechanisms: pull tab, ejector latch, and internal
lock. The engagement mechanism refers to the mechanism required to install/remove the OCP* adapter.
Instructions for OCP* adapter installation and removal for all three configurations are provided in the
following subsections.
Table 2. Supported Intel® Ethernet Network Adapters for OCP*
Description
Interface
iPC
Dual port, RJ45, 10/1 GbE
PCI* 3.0
X710T2LOCPV3
Quad port, SFP+ DA, 4x 10 GbE
PCI* 3.0
X710DA4OCPV3
Dual Port, QSFP28 100/50/25/10 GbE
PCI* 4.0
E810CQDA2OCPV3
Dual Port, SFP28 25/10 GbE
PCI* 4.0
E810XXVDA2OCPV3
For more information on the supported OCP*-compatible Ethernet Network Adapter, see the
Intel® Server
System M50CYP2UR Family Technical Product Specification
.
3.5.1
OCP* Adapter Bay Filler Removal / Installation
The OCP* adapter bay has a filler that needs to be removed before installing any of the OCP* adapter
configurations.
Caution:
If the OCP* adapter is removed and the bay becomes empty again, this filler needs to be reinstalled.
The following steps show how to remove and install OCP* adapter bay filler.