Intel® Server System M20NTP1UR - System Integration and Service Guide
77
•
Ensure the heat sink anti-tilt wire, located over each of the four heat sinks fasteners, is in the
outward position (see Letter “A”).
•
Loosen each fastener (see Letter “B”)
•
Set all four anti-tilt wires on the heat sink to the inward position (see Letter “C”).
•
Carefully grasp the PHM and lift it straight up and off the server board (see Letter “D”).
7.
With the processor facing up, set the PHM down onto a flat surface.
8.
Visually inspect that the processor socket is free of damage or contamination.
Note:
If debris is observed within the processor socket, blow it away gently. Do not use tweezers or any other
hard tools to remove the debris.
If not replacing the processor, install the original plastic socket cover over the processor socket.
Figure 97. Processor Socket Cover Installation
•
Squeeze the finger grips at each end of the cover (see Letter “A”).
•
Carefully lower the cover over the four alignment pins of the bolster plate and onto the
processor socket (see Letter “B”).
•
Release the finger grips to lock the cover in place.
•
Ensure socket cover is locked in place.
Caution:
Do not press down on the center of the socket cover.
Содержание M20NTP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Страница 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Страница 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Страница 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Страница 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...