background image

About This Manual

©

 National Instruments Corporation

ix

80188EB-Based Fieldbus Round Card User Manual

bold

Bold text denotes the names of menus, menu items, parameters, dialog 
box, dialog box buttons or options, icons, windows, Windows 95 tabs, 
or LEDs.

bold italic

Bold italic text denotes a note, caution, or warning.

italic

Italic text denotes emphasis, a cross reference, or an introduction to a 
key concept. This font also denotes text from which you supply the 
appropriate word or value, as in Windows 3.x.

italic monospace

Italic text in this font denotes that you must supply the appropriate 
words or values in the place of these items.

monospace

Text in this font denotes text or characters that you should literally enter 
from the keyboard, sections of code, programming examples, and 
syntax examples. This font is also used for the proper names of disk 
drives, paths, directories, programs, subprograms, subroutines, device 
names, functions, operations, variables, filenames and extensions, and 
for statements and comments taken from programs.

Related Documentation

The following document contains information that you may find helpful 
as you read this manual:

Fieldbus Foundation Specification, which includes the following 
items:

Fieldbus Foundation System Management Services

Function Block Application Process, Part 1

Function Block Application Process, Part 2

Customer Communication

National Instruments wants to receive your comments on our products 
and manuals. We are interested in the applications you develop with our 
products, and we want to help if you have problems with them. To make 
it easy for you to contact us, this manual contains comment and 
configuration forms for you to complete. These forms are in 
Appendix D, Customer Communication, at the end of this manual.

Содержание Intel 80188EB

Страница 1: ...0188EB Based Fieldbus Round Card User Manual 80188EB Based Fieldbus Round Card User Manual January 1998 Edition Part Number 321019C 01 Copyright 1996 1998 National Instruments Corporation All rights r...

Страница 2: ...Denmark 45 76 26 00 Finland 09 725 725 11 France 01 48 14 24 24 Germany 089 741 31 30 Hong Kong 2645 3186 Israel 03 6120092 Italy 02 413091 Japan 03 5472 2970 Korea 02 596 7456 Mexico 5 520 2635 Nethe...

Страница 3: ...PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY THEREOF This limitation of the liability of National Instruments will apply regardless of the form of...

Страница 4: ...Hardware Overview 1 1 Software Overview 1 2 Chapter 2 Hardware Installation Install the Hardware 2 1 Chapter 3 Software Installation Fieldbus Round Card Interface Kit Components 3 1 Install the Softwa...

Страница 5: ...ppendix C Specifications Appendix D Customer Communication Glossary Figures Figure 2 1 Top Side of 80188EB Based Fieldbus Round Card 2 2 Figure 2 2 Bottom Side of 80188EB Based Fieldbus Round Card 2 3...

Страница 6: ...n Block Shell software Use this Intel 80188EB Based Fieldbus Round Card User Manual manual to install the Intel 80188EB based Fieldbus Round Card Use the MC68331 Based Fieldbus Round Card User Manual...

Страница 7: ...ucture the Data Link Configuration section of your Device Configuration ini file Appendix B System Management Configuration Section Format explains how to structure the System Management Configuration...

Страница 8: ...yntax examples This font is also used for the proper names of disk drives paths directories programs subprograms subroutines device names functions operations variables filenames and extensions and fo...

Страница 9: ...us Foundation H1 specification The Fieldbus Round Card uses the Intel 80188EB embedded processor and a programmable 256 KB 8 Flash to run the Stack Interface Library Function Block Shell and user appl...

Страница 10: ...the application that is loaded in the Flash Software Overview The software supplied with the Fieldbus Round Card Interface Kit includes the NI FBUS Function Block Shell which is an Application Progra...

Страница 11: ...antistatic plastic package to a metal part of your computer chassis before removing the board from the package Install the Hardware Perform the following steps to install the Fieldbus Round Card 1 Co...

Страница 12: ...ldbus Round Card In Figure 2 2 W2 shows the pinout of the user electronics connector and U9 shows where your Flash should be placed after burning Chapter 4 Interfacing to Your Round Card describes the...

Страница 13: ...ed Fieldbus Round Card User Manual Figure 2 2 Bottom Side of 80188EB Based Fieldbus Round Card Your hardware is now installed Proceed to Chapter 3 Software Installation for instructions on installing...

Страница 14: ...ry for Borland C C 4 5 Sample function block templates for all standard Foundation Fieldbus function blocks Sample function block configuration files C language header files for interfacing to the NI...

Страница 15: ...us Round Card User Manual 3 2 National Instruments Corporation 4 The interactive installation program installs the software into the directory of your choice Your software installation is now complete...

Страница 16: ...ctor The signals are described as follows 3VOUT The Fieldbus Round Card has a 3 9 V at 8 mA output that you can use to power the user electronics To activate the 3 9 V output on the W2 connector of th...

Страница 17: ...signed to isolate your application as much as possible from the specifics of the Fieldbus For more specific information about the Function Block Shell API consult the NI FBUS Function Block Shell Refe...

Страница 18: ...the sample device templates using a text editor such as MS DOS Edit or Windows Notepad Choose the sample device template that most closely matches your device For example if the main function of your...

Страница 19: ...izer Writing Function Block Callbacks The callback functions that you must develop are responsible for the following main functions Handling read and write requests from the network Executing your fun...

Страница 20: ...ter you have generated your configuration ini file you must run the Configuration Generator to create a C source file that contains your configuration This step is described in the next section Conver...

Страница 21: ...ow single byte enumeration where possible For the Borland C 4 5 compiler this option is b After you have compiled the files you must link them with the National Instruments Round Card library nistack...

Страница 22: ...ing steps to burn the Flash with the niBurn utility 1 Power up the Round Card in PROG Mode see the Hardware Overview section of Chapter 1 Introduction for more information about PROG Mode 2 Make sure...

Страница 23: ...OM port you specify See the Interfacing to the Hardware section earlier in this chapter for the connections of serial port 1 on the user electronics connector The niBurn utility contacts the Round Car...

Страница 24: ...onfiguration Generator automatically configures your board When a parameter is changed over the Fieldbus the parameter is updated in nonvolatile memory Following is a description of the format of the...

Страница 25: ...ddress Addresses between 0xf8 and 0xfb are temporary addresses A device with a temporary address on the bus is eventually assigned a fixed address to be operational Addresses between 0xfc and 0xff are...

Страница 26: ...ile through the Configuration Generator automatically configures your card When a parameter is changed over the Fieldbus the parameter is updated in nonvolatile memory Following is a description of th...

Страница 27: ...0 255 seconds 10 macrocycleDuration 32 bit unsigned integer 1 32 ms 0x8000 primaryTimeMaster 0 255 n a none devID ASCII string identifier of this device n a none pdTag ASCII string tag for this devic...

Страница 28: ...2 1 52 cm 2 44 0 6 in Processor Intel 80188EB 8 MHz system clock Fieldbus Interface Fuji Electric Frontier 1 bus powered 31 25 kb s Fieldbus Power Supply 14 32 V at 20 mA at 8 MHz 50 terminated Power...

Страница 29: ...these systems does not answer your questions we offer fax and telephone support through our technical support centers which are staffed by applications engineers Electronic Services National Instrume...

Страница 30: ...to obtain support Telephone Fax Australia 03 9879 5166 03 9879 6277 Austria 0662 45 79 90 0 0662 45 79 90 19 Belgium 02 757 00 20 02 757 03 11 Brazil 011 288 3336 011 288 8528 Canada Ontario 905 785 0...

Страница 31: ...______________________________________________ _______________________________________________________________________________ National Instruments hardware product model __________ Revision _________...

Страница 32: ..._________________________________________________________ Microprocessor ___________________________________________________________________ Clock frequency or speed __________________________________...

Страница 33: ..._________________________________________________________________ _______________________________________________________________________________ ______________________________________________________...

Страница 34: ...or Information Interchange bit A binary digit a digit 1 or 0 in the representation of a number in binary notation byte Eight related bits of data DD Device Description DMA Direct memory access EPROM E...

Страница 35: ...tes of memory MB megabytes of memory OD Object Dictionary PC Personal computer PROM Programmable read only memory RAM Random access memory s Seconds snap Read from the communications stack SRAM Serial...

Отзывы: