Intel Express 10 Скачать руководство пользователя страница 1

Intel Express 10/100
Fast Ethernet Switch

User Guide

Part No. 663096-001

Содержание Express 10

Страница 1: ...Intel Express 10 100 Fast Ethernet Switch User Guide Part No 663096 001...

Страница 2: ...o OR 97124 6497 Intel Corporation assumes no responsibility for errors or omissions in this manual Nor does Intel make any commitment to update the information contained herein Other product and corpo...

Страница 3: ...etwork WAN or multi floor environment 12 Repeater count limitations 14 Chapter 2 Configuring and Managing the Switch 15 Accessing the Console Manager 16 Using the Console Manager 17 Entering commands...

Страница 4: ...ds 51 Custom filtering 54 VLAN Commands 56 Spanning Tree Commands 60 Port Configuration Commands 65 Statistics Commands 66 Chapter 4 Troubleshooting 71 General Problems 72 Flow Control Problems 73 App...

Страница 5: ...onfigure the switch to work with an SNMP compliant Network Management System NMS See Chapter 2 if you want to use the Console Manager to change port configurations set a port for full duplex or manual...

Страница 6: ...et ip conf command set ip conf 192 1 1 64 255 255 255 0 192 1 1 255 E Replace these addresses with the numbers for your network Specify the IP address netmask subnet mask and broadcast address default...

Страница 7: ...Mbps segment The switch also has two slots for optional two port media adapters such as 100BASE TX or 100BASE FX The switch also has a built in SNMP Simple Network Management Protocol agent and can b...

Страница 8: ...or 5 UTP for 10BASE T devices Limit the distance between devices connected with UTP cable to 100 meters Use a crossover cable when directly connecting a hub also called a repeater or concentrator to...

Страница 9: ...are connected while it updates the internal SNMP agent Rcv Receive Lights when packets are received on this port even if they are not forwarded Coll Fdpx Collision default or Full Duplex Blinks when c...

Страница 10: ...crossover See page 8 for more information Management status LEDs Management status LEDs provide information about the overall operation of the switch and its SNMP management components SNMP Simple Net...

Страница 11: ...you re running at 10 Mbps or 100 Mbps However you can extend the total diameter by installing a fiber optic media adapter and using fiber optic connections between switches or between the switch and...

Страница 12: ...DI For direct connection to another MDI X port most hubs and some switches you must use a crossover cable NIC RJ 45 MDI Switch Hub RJ 45 MDI X Switch Hub RJ 45 MDI X Switch Hub RJ 45 MDI X A straight...

Страница 13: ...ub repeater and the EtherExpress family of adapters server or workstation These apply to the majority of switches and hubs and all servers or workstations For this connection Use this cable Switch to...

Страница 14: ...roup environment In the mixed 10 and 100 Mbps environment workgroup clients should be connected to a hubs such as the Intel Express 10 100BASE TX Stackable Hub All hub stacks should be connected to th...

Страница 15: ...e concerns about server access or other security issues configure security virtual LANs SVLANs to prevent segments ports from accessing other ports In the example on the previous page you may want to...

Страница 16: ...g the Wide Area Network WAN or multi floor environment Connections to the backbone are most effective using fiber optic cabling especially when devices are separated by multiple floors or buildings Th...

Страница 17: ...connections to repeaters Since repeaters aren t capable of full duplex mode operation you re restricted to 160 meters of fiber optic cable between the Express Switch and a repeater Multi workgroup se...

Страница 18: ...ASE T repeaters hubs between the switch and any workstation or server However only three of the repeaters can have devices attached 100BASE TX There can be one class 1 repeater hub between the switch...

Страница 19: ...n and turning the power on However if you need to change the default configuration or manage the switch there are two ways Use SNMP compliant management software such as Intel LANDesk Network Manager...

Страница 20: ...t no username or password is assigned If you enter a password it becomes active only after you reset the switch or turn off the power If you want the password to take effect immediately use the set pa...

Страница 21: ...asic system status information Items in angle brackets mean you need to enter a specific value For example IPaddress represents an IP address in dotted decimal notation such as 123 1 1 7 Items in and...

Страница 22: ...l arg 1 aging time in seconds The Console Manager provides a history of the last several commands you entered To cycle through them press or cP at the prompt To correct a command line use the followin...

Страница 23: ...nt and trap options Switching database commands aging time management and switching database entry management VLAN commands management of security virtual LANs virtual broadcast domains and port mirro...

Страница 24: ...nager Session Refer to the diagram below when reading the sample configuration procedures on pages 21 through 29 Procedures using this diagram Configuring the SNMP agent for IP page 21 Configuring a p...

Страница 25: ...immediately and saved in NVRAM 192 1 1 255 is the address of the router in the diagram on page 20 If you previously assigned an IP configuration the command changes only the NVRAM To use the new para...

Страница 26: ...onfigure the device on the other end for full duplex In the diagram on page 20 you d configure the adapter in the file server for full duplex 2 Get the current port settings using the get port cfg com...

Страница 27: ...other port on the switch VBDs reduce broadcast traffic on the network while allowing other types of traffic to pass through Commands used set sec vlan Sets up an SVLAN del sec vlan Deletes an SVLAN g...

Страница 28: ...xperiences a high volume of traffic just within its own workgroup Broadcast traffic from other workgroups adds to the problem By grouping port 8 and port 6 into a VBD the Engineering workgroup can acc...

Страница 29: ...t is an Ethernet segment For example if a high volume of traffic is forwarded from the CD server on port 4 to the payroll workgroup on port 3 but no other workgroups access the CD server move the serv...

Страница 30: ...l ports 0 Frm multicast 16017 Frm lost fctrl 0 Transmit OK 1404387 Forward to port FRAMES BYTES 1 0 0 2 0 0 3 218103808 60 4 1419823 842711315 5 0 0 6 0 0 7 0 0 In this example a station on port 3 is...

Страница 31: ...such as the Intel Express Stackable hub can only be half duplex Detecting bad or poor quality cable If a high percentage of CRC Errors with respect to Transmit OK occur it could indicate poor quality...

Страница 32: ...r or an Alignment Error Alignment Errors The number of frames detected that contain partial octets and don t pass the FCS check Runt Errors The number of frames detected that are less than the minimum...

Страница 33: ...he port etherStatsRuntPkts The number of frames detected that are less than the minimum permitted frame size and have a good FCS etherStatsJabberPkts The number of packets received that were longer th...

Страница 34: ...related commands system System related commands ip IP related commands snmp SNMP related commands switch db Switching Database related commands vlan Virtual LANS related commands port cfg Port Configu...

Страница 35: ...Changes the console password System Commands sys stat Displays system status get stst level Displays the selftest level set stst level none short long Changes the selftest level warm reset Performs a...

Страница 36: ...nt parameters filename set par file filename Sets the SNMP agent parameters filename for automatic setup set fg param dest source fill_byte length Sets the Ethernet frame generator parameters start fg...

Страница 37: ...les or disables the BOOTP process ping IPaddress number 0 Contacts another IP device ping stop Stops the ping process get def ttl Displays the running default TTL time to live value set def ttl number...

Страница 38: ...lock on perm mac_address sport dport Adds a custom filter entry del cf entry run nvram mac_address sport Deletes a custom filter entry get nv cftbl Displays the saved custom filters table get nv cfilt...

Страница 39: ...spanning tree for the next session get st bcfg Displays the spanning tree bridge parameters get st pcfg Displays the spanning tree port parameters table get st syscfg Displays the spanning tree syste...

Страница 40: ...on or off Switching Statistics Commands clr cnt Resets the counters for Ethernet and bridging statistics get eth cnt port number Displays the Ethernet statistics for a port get colls cnt port number D...

Страница 41: ...prompt login Exits the Console Manager but doesn t disconnect a Telnet session Use this command to password protect the console terminal while a Telnet session is running logout Ends the local Consol...

Страница 42: ...sion SNMP Object ID is 1 3 6 1 4 1 629 1 1 3 System MAC Address 00 A0 C9 00 20 D9 Switching Data Base Size 4096 entries Total uptime hundredths of seconds 111151888 Total uptime days hh mm ss format 1...

Страница 43: ...witch performs a self test each time you reset it with the cold reset command or when you cycle the power The default is none warm reset Resets the SNMP agent software without resetting the switch it...

Страница 44: ...baudrate in SLIP mode changed to 9600 bps To switch back to Administrative Interface Mode press CR three times Note that the Administrative Interface Mode baudrate will be 9600 get sw file Displays th...

Страница 45: ...e name of the SNMP agent parameter file set par file set par file filename Sets the name of the SNMP agent parameter file to be downloaded by BOOTP The filename must match the name of the parameter fi...

Страница 46: ...In the sections that follow IP Configuration lists general configuration commands Ping lists commands that describe the ping ability of the agent and Address Resolution Protocol lists ARP commands IP...

Страница 47: ...IP address If no IP configuration was previously set default configuration the new values are saved in NVRAM and used immediately Otherwise the new values are stored in NVRAM but you must use the war...

Страница 48: ...way IP address which specifies the router used to access a different IP network The default value for this setting is 0 0 0 0 no gateway You can also set the default gateway using the set ip conf comm...

Страница 49: ...nded as a traffic generator so it s best to avoid using an endless ping To stop the ping use cC or enter the ping stop command SYS_console ping 192 1 1 1 10 129 001 001 001 Alive echo reply id 297 seq...

Страница 50: ...t Adds an entry to the ARP table manually port is the switch port the device is connected to del arp entry del arp entry IPaddress Deletes entries from the ARP table If you enter an IP address the mat...

Страница 51: ...rings one for the two types of access read mode permits read access to all the objects in the MIB but doesn t allow write access write mode permits read and write access to all objects in the MIB get...

Страница 52: ...hether the Express 10 100 Switch issues an authentication trap which NMSs up to five the SNMP agent sends traps to get auth Displays the authentication trap setting By default authentication trap mess...

Страница 53: ...IPaddress Removes a station from the trap table SYS_console del trap 129 1 1 7 Entry 129 1 1 7 trap comm deleted Switching Database Commands Use the commands listed in this section to manage the switc...

Страница 54: ...ase control commands lists commands relevant to standard MAC addresses for example determining the behavior of the switch when it sees a particular address The second section Custom filtering lists co...

Страница 55: ...C5 00 59 E6 4 20 00 00 92 94 01 54 1 21 00 C0 1D 01 06 20 1 22 00 40 05 2B 0A 26 5 23 00 40 05 29 1E DE 7 24 00 40 05 2B 17 37 4 25 08 00 20 76 72 89 2 SYS_console get lt 16 Entry MAC Address LOCK SEL...

Страница 56: ...entry 15 Deleting entry at index 15 OK del lt addr del lt addr mac_address Deletes the switching database entry that matches the specified MAC address SYS_console del lt addr 00 40 05 2b 59 4c Deleti...

Страница 57: ...update in the running database OK SYS_console set lt age all 100 Aging Period update in NVRAM OK Aging Period update in the running database OK Custom filtering Use custom filters to ensure a device...

Страница 58: ...won t be aged out but will be lost when the switch is reset lock off indicates the entry can be aged out normally perm indicates the entry is written to NVRAM and remains after a reset sport is a hexa...

Страница 59: ...LE Entry MAC Address 1 00 00 00 11 11 11 get nv cfilt get nv cfilt mac_address Displays the custom filter associated with mac_address from the custom filter table stored in NVRAM VLAN Commands Use VLA...

Страница 60: ...orwarded to their destinations only if the destination is marked with a in the source port s row Ports don t need to be forwarded to themselves SYS_console get con matrix VLAN CONNECTIVITY MATRIX SRC...

Страница 61: ...et vbc tbl command to see a list of domain ID numbers get vbc tbl get vbc tbl run nvram Displays the list of defined virtual broadcast domains SYS_console get vbc tbl run RUNTIME VIRTUAL BROADCAST DOM...

Страница 62: ...AN and ports 1 2 and 5 are an SVLAN This means that ports 1 and 2 can talk to each other and to ports 3 and 5 but 3 and 5 can t talk to each other set mon port set mon port port Sets the port to be mo...

Страница 63: ...nsequently the workstation has two paths to the switch In Ethernet this isn t allowed and one of the switch ports must be turned off Spanning tree sends out configuration messages and automatically de...

Страница 64: ...g tree protocol Enabled is the default Enabling or disabling spanning tree doesn t take effect until the SNMP agent is reset warm reset cold reset or turning the power off and then on again get st bcf...

Страница 65: ...0 1a00 0a5b 0 8000 0020 1a00 0a5b 8005 6 128 fwd 10 8000 0020 1a00 0a5b 0 8000 0020 1a00 0a5b 8006 7 128 fwd 10 8000 0020 1a00 0a5b 0 8000 0020 1a00 0a5b 8007 8 128 fwd 10 8000 0020 1a00 0a5b 0 8000 0...

Страница 66: ...ge is operating as the root bridge Bridges not acting as the root use the root bridge s Max Age parameter maxage is in seconds from 6 to 40 However the corresponding MIB variable dot1dStpBridgeMaxAge...

Страница 67: ...s from 400 to 3000 and must be a multiple of 100 set prt prio set prt prio port_number port_priority Sets the spanning tree port priority port_number is the decimal port number and port_priority is a...

Страница 68: ...rt LAN type ETH10 100 indicates the port can operate at 10 or 100 Mbps Link status ON or OFF Physical interface type TPFD indicates Twisted pair TP Ethernet Full Duplex FD capable Speed select ASENSE...

Страница 69: ...The default is on If the port is in full duplex mode flow control is turned off Flow control or full duplex or neither can be active but not both One exception is between two Express 10 100 Switches S...

Страница 70: ...identical to the Ethernet like collisions statistics group of the Ethernet MIB and displays the collision count distribution for this port If a packet still collides on the 16th count the packet is d...

Страница 71: ...llisions 36 get sdist cnt get sdist cnt port Displays the RMON statistics packet size histogram for port SYS_console get sdist cnt 1 RMON Packet Size Distribution Counters for port 1 etherStatsPkts64O...

Страница 72: ...ts or bytes represents filtered frames Filtered frames are ones that don t need to be forwarded because they re destined for the same port they came in on SYS_console get br cnt 1 Ethernet Switching C...

Страница 73: ...the switch This amount is usually insignificant SYS_console get mgm brcnt Management Port Counters Frm Received 15506 Bytes Received 1691744 Frm Filtered 15506 Frm Received Bcast 15506 Frm Transmited...

Страница 74: ...of the Express 10 100 Switch printed on the back side of the switch The firmware revision number displayed by the Console Manager sys stat message The configuration of the equipment connected to the s...

Страница 75: ...t Each switch port can be forced to either 10 or 100 Mbps although auto detect is the default Also other devices connected to the switch may be capable of operating at 10 or 100 Mbps See page 66 for i...

Страница 76: ...2 Port 1 buffer Port 2 buffer 9 Restore the switch s defaults with the init nvram command and then reset the switch with the cold reset command Flow Control Problems During times of peak network usage...

Страница 77: ...e segment as the device they re talking to When Ethernet bandwidth is temporarily insufficient for the traffic three actions are possible drop packets use flow control or segment the network Buffering...

Страница 78: ...product specifications and supported standards for SNMP and MIB features Default Configuration System Internal software filename flash12 hex Database aging time 300 seconds SNMP Read community public...

Страница 79: ...sories on next page Console Manager Communications parameters 9600 baud 8 N 1 Login name None Password None Prompt SYS_console Spanning tree Spanning tree Enabled Bridge priority 32768 0 65535 Bridge...

Страница 80: ...ss and port Accessories Two port 100BASE TX expansion module Intel order code ES101MATX Two port 100BASE FX expansion module Intel order code ES101MAFX Redundant power supply RPS connector RPS must be...

Страница 81: ...Distances Switch to switch or switch to NIC Category 5 UTP 328 feet 100 meters 62 5 125 multimode fiber 1 2 miles 2 kilometers at full duplex 1351 feet 412 meters at half duplex Switch to repeater Cat...

Страница 82: ...is terminated in an IEC 320 attachment plug The other end is terminated as required by the country where it will be installed Electromagnetic Emissions and Safety Agency Approval FCC Part 15 Subpart...

Страница 83: ...Types RFC 1573 Evolution of the Interfaces Group of MIB II 1 94 RFC 1493 Definitions of Managed Objects for Bridges 7 93 RFC 793 Transmission Control Protocol RFC 854 Telnet Protocol Specification RFC...

Страница 84: ...i ninety 90 days from the return shipping date or ii the period of time remaining on the original one 1 year warranty This warranty gives you specific legal rights and you may have other rights which...

Страница 85: ...h either new or remanufactured product or parts and the returned product becomes Intel s property Intel warrants the repaired or replaced product to be free from defects in material and workmanship fo...

Страница 86: ...WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WARNING The system is designed t...

Страница 87: ...tilata e lontana da fonti di calore compresa la luce solare diretta Al riparo da urti e lontana da fonti divibrazione Isolata dai forti campi magnetici prodotti da dispositivi elettrici In aree sogget...

Страница 88: ...state 44 enabling or disabling 44 Bridge See Spanning tree Broadcast address setting 44 Cabling crossover cables 4 fiber optic 7 maximum distances 78 null modem cable using 6 requirements 4 7 straigh...

Страница 89: ...entry command 53 del sec vlan command 58 del trap command 50 del vbc domain command 58 Diagnostics viewing the last failure 40 Distance limitations fiber optic 7 UTP 7 Electrical specifications 79 En...

Страница 90: ...installation rack mount 4 shelf mount 4 Hardware installation and network topology 3 14 help kbd command 38 Humidity limits 79 init nvram command 41 Installation hardware 3 rack mount 4 Installing det...

Страница 91: ...duplex 22 status 39 Power Pwr LED 6 Prompt changing 38 Protocol analyzer attaching 59 Quick Start 1 2 Rack mount installation 4 Rcv Receive LED 5 Remote access 16 Repeaters cabling for 9 count limita...

Страница 92: ...boot and configuration 78 buffers 77 electrical 79 environment 79 general indicators 78 interfaces 78 mounting 78 network management 77 power cord 79 standards supported 78 Specifications continued s...

Страница 93: ...d general product information Intel Customer Support Technicians Free support for 90 days You can speak with our technical support professionals free of charge for 90 days after your initial call Othe...

Отзывы: