Intel
®
Celeron
®
D Processor in the 775-Land LGA Package
Thermal Design Guide
47
Order #
303730
Case Temperature Reference Methodology
Appendix D Case Temperature Reference
Methodology
D.10
Objective and Scope
This appendix defines a reference procedure for attaching a thermocouple to the IHS of an
FC-LGA4 processor package for T
C
measurement. This procedure takes into account the specific
features of the FC-LGA4 package and of the LGA775 socket for which it is intended.
It describes the recommended equipment for the reference thermocouple installation, including
tools and adhesive part numbers.
D.11
Definitions
Definitions of common acronyms used in this appendix are given in the table below:
D.12
Supporting Test Equipment
To apply the reference thermocouple attach procedure, it is recommended to use the equipment (or
equivalent) given in the table below.
Table 8. Definitions
Term
Definition
TTV
Thermal Test Vehicle
IPA
Isopropyl Alcohol
DMM
Digital Multi Meter
IHS
Integrated Heat Spreader
Table 9. Supporting Test Equipment (Sheet 1 of 2)
Item
Description
Part Number
Measurement and Output
Microscope
Olympus* Light microscope or equivalent
SZ-40
DMM
Digital Multi Meter for resistance measurement
Not Available
Test Fixture(s
)
Micromanipulator
(See Note below)
Micromanipulator set from YOU* Ltd. or equivalent.
Mechanical 3D arm with needle (not included) to maintain TC
bead location during the attach process.
YOU-3
Miscellaneous Hardware
Loctite* 498 Adhesive
Super glue w/thermal characteristics
49850
Adhesive Accelerator
Loctite* 7452 for fast glue curing
18490
Kapton* Tape
For holding thermocouple in place
Not Available