Case Temperature Reference Metrology
96
Thermal and Mechanical Design Guidelines
Figure 7-27. Solder Station Setup
21.
Remove the land side protective cover and place the device to be soldered in the
solder station. Make sure the thermocouple wire for the device being soldered is
exiting the heater toward you.
Note:
Do not touch the copper heater block at any time as this is very hot.
22.
Move a magnified lens light close to the device in the solder status to get a better
view when the solder begins to melt.
23.
Lower the Heater block onto the IHS. Monitor the device IHS temperature during
this step to ensure the maximum IHS temperature is not exceeded.
Note:
The target IHS temperature during reflow is 150 °C ±3 °C. At no time should the IHS
temperature exceed 155 °C during the solder process as damage to the device may
occur.
Содержание AT80569PJ080N - Core 2 Quad 3 GHz Processor
Страница 24: ...Processor Thermal Mechanical Information 24 Thermal and Mechanical Design Guidelines...
Страница 80: ...Heatsink Clip Load Metrology 80 Thermal and Mechanical Design Guidelines...
Страница 82: ...Thermal Interface Management 82 Thermal and Mechanical Design Guidelines...
Страница 106: ...Balanced Technology Extended BTX System Thermal Considerations 106 Thermal and Mechanical Design Guidelines...
Страница 108: ...Fan Performance for Reference Design 108 Thermal and Mechanical Design Guidelines...
Страница 120: ...Mechanical Drawings 120 Thermal and Mechanical Design Guidelines Figure 7 50 Reference Fastener Sheet 1...
Страница 121: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 121 Figure 7 51 Reference Fastener Sheet 2...
Страница 122: ...Mechanical Drawings 122 Thermal and Mechanical Design Guidelines Figure 7 52 Reference Fastener Sheet 3...
Страница 123: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 123 Figure 7 53 Reference Fastener Sheet 4...