Thermal Management Logic and Thermal Monitor Feature
Thermal and Mechanical Design Guidelines
35
Regardless of the configuration selected, PROCHOT# will always indicate the thermal
status of the processor.
The power reduction mechanism of thermal monitor can also be activated manually
using an “on-demand” mode. Refer to Section 4.2.5 for details on this feature.
4.2.5
On-Demand Mode
For testing purposes, the thermal control circuit may also be activated by setting bits
in the ACPI MSRs. The MSRs may be set based on a particular system event (such as,
an interrupt generated after a system event), or may be set at any time through the
operating system or custom driver control thus forcing the thermal control circuit on.
This is referred to as “on-demand” mode. Activating the thermal control circuit may be
useful for thermal solution investigations or for performance implication studies. When
using the MSRs to activate the on-demand clock modulation feature, the duty cycle is
configurable in steps of 12.5%, from 12.5% to 87.5%.
For any duty cycle, the maximum time period the clocks are disabled is ~3
µ
s. This
time period is frequency dependent, and decreases as frequency increases. To achieve
different duty cycles, the length of time that the clocks are disabled remains constant,
and the time period that the clocks are enabled is adjusted to achieve the desired
ratio. For example, if the clock disable period is 3 µs, and a duty cycle of ¼ (25%) is
selected, the clock on time would be reduced to approximately 1
µ
s [on time (1
µ
s)
÷
total cycle time (3 + 1)
µ
s = ¼ duty cycle]. Similarly, for a duty cycle of 7/8 (87.5%),
the clock on time would be extended to 21
µ
s [21
÷
(21 + 3) = 7/8 duty cycle].
In a high temperature situation, if the thermal control circuit and ACPI MSRs
(automatic and on-demand modes) are used simultaneously, the fixed duty cycle
determined by automatic mode would take precedence.
Note:
On-demand mode cannot activate the power reduction mechanism of Thermal Monitor
2
4.2.6
System Considerations
Intel requires the Thermal Monitor and Thermal Control Circuit to be enabled for all
processors. The thermal control circuit is intended to protect against short term
thermal excursions that exceed the capability of a well designed processor thermal
solution. Thermal Monitor should not be relied upon to compensate for a thermal
solution that does not meet the thermal profile up to the thermal design power (TDP).
Each application program has its own unique power profile, although the profile has
some variability due to loop decisions, I/O activity and interrupts. In general, compute
intensive applications with a high cache hit rate dissipate more processor power than
applications that are I/O intensive or have low cache hit rates.
The processor TDP is based on measurements of processor power consumption while
running various high power applications. This data is used to determine those
applications that are interesting from a power perspective. These applications are then
evaluated in a controlled thermal environment to determine their sensitivity to
activation of the thermal control circuit. This data is used to derive the TDP targets
published in the processor datasheet.
Содержание AT80569PJ080N - Core 2 Quad 3 GHz Processor
Страница 24: ...Processor Thermal Mechanical Information 24 Thermal and Mechanical Design Guidelines...
Страница 80: ...Heatsink Clip Load Metrology 80 Thermal and Mechanical Design Guidelines...
Страница 82: ...Thermal Interface Management 82 Thermal and Mechanical Design Guidelines...
Страница 106: ...Balanced Technology Extended BTX System Thermal Considerations 106 Thermal and Mechanical Design Guidelines...
Страница 108: ...Fan Performance for Reference Design 108 Thermal and Mechanical Design Guidelines...
Страница 120: ...Mechanical Drawings 120 Thermal and Mechanical Design Guidelines Figure 7 50 Reference Fastener Sheet 1...
Страница 121: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 121 Figure 7 51 Reference Fastener Sheet 2...
Страница 122: ...Mechanical Drawings 122 Thermal and Mechanical Design Guidelines Figure 7 52 Reference Fastener Sheet 3...
Страница 123: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 123 Figure 7 53 Reference Fastener Sheet 4...