background image

 

Intel

®

 Local Control Panel for EPSD 

Platforms Based on Intel

®

 Xeon

®

 

Processor E5 
4600/2600/2400/1600/1400 
Product Families 

Technical Product Specification 

Intel order number G83726-001 

 

Revision 1.0 

December, 2012 

Enterprise Platforms and Services Division - Marketing

 

 

 

 

Содержание A1U2ULCP

Страница 1: ...PSD Platforms Based on Intel Xeon Processor E5 4600 2600 2400 1600 1400 Product Families Technical Product Specification Intel order number G83726 001 Revision 1 0 December 2012 Enterprise Platforms a...

Страница 2: ...MPLOYEES OF EACH HARMLESS AGAINST ALL CLAIMS COSTS DAMAGES AND EXPENSES AND REASONABLE ATTORNEYS FEES ARISING OUT OF DIRECTLY OR INDIRECTLY ANY CLAIM OF PRODUCT LIABILITY PERSONAL INJURY OR DEATH ARIS...

Страница 3: ...4 RMM LAN RL Configuration 10 3 5 5 Power Pow 11 3 5 6 Last POST Code Last PC 11 3 6 Configuration Conf Menu 11 3 6 1 BMC LAN BL Configuration 11 3 6 2 RMM LAN RL Configuration 13 3 6 3 Boot Device BD...

Страница 4: ...igure 17 Last BIOS POST Code 11 Figure 18 Configure Menu Items 11 Figure 19 BMC IP Configuration Menu 11 Figure 20 BMC IP Source Configuration Menu 11 Figure 21 Screen shot for Configuring IP Address...

Страница 5: ...el Tray from the Pedestal server system 23 Figure 38 Installing the Intel A4ULCP Local Control Panel in a Pedestal server system 24 Figure 39 Removing the Intel A4ULCP Local Control Panel from a Pedes...

Страница 6: ...List of Figures Intel Local Control Panel for EPSD Platforms TPS Intel order number G83726 001 Revision 1 0 vi This page is intentionally left blank...

Страница 7: ...ntel Local Control Panel allows a user to monitor the health of an Intel server platform or configure an Intel server for remote IPMI management This allows for monitoring configuration and control of...

Страница 8: ...0SC R1000GZ GL and R2000GZ GL Families Product Order Code A4ULCP is for all Intel Pedestal Server Systems P4000CR P4000CP P4000GP P4000IP P4000SC S2400GP P4000M S2400SC P4000M S2600CO P4000M and S2600...

Страница 9: ...shows where the LCP should be mounted in an Intel Rack Server System Figure 3 Mounting the A1U2ULCP in an Intel 2U Server Chassis Figure 4 Mounting the A1U2ULCP in an Intel 1U Server Chassis The foll...

Страница 10: ...ct the content that needs to be displayed on the LCD screen by operating these buttons The figures below show the Intel Local Control Panel buttons and configuration Label Description Functionality A...

Страница 11: ...indicator K NIC 3 LED NIC 3 Activity LED indicator L System Reset Button reset and re initialize the system M HDD Activity LED hard drive activity LED indicator N System Status LED show the current h...

Страница 12: ...baseboard BMC detects the problem has been cleared the amber backlight is deactivated to turn on the green backlight 2 3 4 External Connectors The Intel Local Control Panel has either one or two USB...

Страница 13: ...s active error messages when the system is not healthy Provides the ability to quickly see asset information on system without having to open the chassis Provides basic server management configuration...

Страница 14: ...y one of the following four menu items Figure 10 Main Menu If the user selects menu item then the LCD displays the previous screen that is Banner Error string Selecting the menu item means moving the...

Страница 15: ...on will stop scrolling and the corresponding action for that button press will be taken Switching between scrolling and freezing the screen and vice versa is not supported due to the limitation of LCD...

Страница 16: ...tem GUID System UUID stored by BIOS CSTR Customizable String Custom string placed by the OEM end user Selecting any item in the above screen displays its value 3 5 3 BMC LAN BL Configuration Selecting...

Страница 17: ...user selects Conf item in the main menu then the following options will be displayed to configure Figure 18 Configure Menu Items The following sub sections will explain individual items of the configu...

Страница 18: ...in the same item 2 If the cursor is under last position inside the second menu item then a Right button will move the cursor to next item that is Set 3 If the cursor is under first position inside the...

Страница 19: ...hen the following options will be displayed The selected item will be set as the next boot option Figure 23 Boot options configuration menu 3 6 4 Banner Ban When the user selects Ban in the Conf menu...

Страница 20: ...only It shall not display an informational message If the system is healthy then it displays System Health Ok BIP BMC IP Displays BMC s IP address as banner RIP RMM IP Displays RMM s IP address as ba...

Страница 21: ...e letter A 2 Remove the two screws see letter B 3 Slide out the bracket from server chassis together with cables see letter C 4 Remove the two screws and slide out the front USB connecter from the bra...

Страница 22: ...rver system 4 2 Removing the Intel A1U2ULCP Local Control Panel in a 1U server system 1 Disconnect the Intel Local Control Panel cable and the front USB cable from the server board see letter A 2 Remo...

Страница 23: ...A1U2ULCP Local Control Panel in a 1U server system 5 Install the front USB connecter to the bracket and secure the two screws see letter E 6 Install the bracket together with cables see letter F 7 Se...

Страница 24: ...ree screws to release the hard drive cage see letter A For 2U system with 3 5 hard drive configuration remove the six screws to release the hard drive cage Please refer to the Intel Server System Serv...

Страница 25: ...cables see letter H 11 Secure the two screws see letter I Figure 31 Installing the Intel A1U2ULCP Local Control Panel in a 2U server system 12 Install the cage into server chassis see letter J For 2U...

Страница 26: ...For 2U system with 2 5 hard drive configuration remove the stiffener first Please refer to the Intel Server System Service Guide for detailed instructions 3 Disconnect the Intel Local Control Panel c...

Страница 27: ...out the Intel Local Control Panel from server chassis together with cables see letter E 8 Remove the two screws and slide out the front USB connecter from the bracket see letter F Figure 34 Removing...

Страница 28: ...d drive configuration secure the three screws see letter K For 2U system with 3 5 hard drive configuration secure the six screws Please refer to the Service Guide of your Intel Server System for detai...

Страница 29: ...panel cable and USB cable from motherboard see letter A 2 Slide the front panel tray out from the chassis see letter B and C 3 Refer to Replacing the Front Panel Board to remove front panel board fro...

Страница 30: ...ULCP Local Control Panel in a Pedestal server system 4 6 Removing the Intel A4ULCP Local Control Panel in a Pedestal server system 1 Disconnect all cables from the motherboard see letter A 2 Slide the...

Страница 31: ...rder number G83726 001 25 Figure 39 Removing the Intel A4ULCP Local Control Panel from a Pedestal server system 4 Insert the front panel tray into the chassis see letter H 5 Connect all cables of the...

Страница 32: ...ee Letter A securing the front panel board and remove the front panel board see Letter B Figure 41 Removing the Front Panel Board 3 Remove the cap on the front panel board power button and install the...

Страница 33: ...properly grounded plugs To help protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply...

Страница 34: ...ate components inside your computer To prevent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You ca...