Created by:
Approved by:
Rev.No:
For Stage:
Release Date:
Page: 8 Of 57
Model No: 3420
Drawing No:
Customer :
Model No:
H 520 PLUS
Rev. Date:
ALIGNMENT PROCEDURE
Step
Setting
Connection
Adjuster
Adjust for
1
Frequency adjustment
MIC : Receive
Volume : optional
Squelch : optional
CH selector : 19
Frequency counter to
dummy load (Figure
1).
X302 27.185MHz
±
300Hz
2
VCO Voltage adjustment
MIC : Receive
Volume : optional
Squelch : optional
CH selector : 19
Connect DC
voltmeter at test
point1
(Figure 2).
T302
1.4V at RX.
Figure 1 Figure
2