Integrated Visual Data Technology Inc. ED3-RFID SkidWeigh Plus Series Скачать руководство пользователя страница 1

!

                     

 

Installation & Calibration Manual

              

ED3/ED4-RFID SkidWeigh Plus 

            

                                                       

Lift Truck On-board Check Weighing Scale  

                                                     

Optional:

 Impact Monitor, OSHA Pre-Shift Checklist, Overload Warning, Vehicle Utilization,         

Authorized Operator Vehicle Access Control 

     

                                                      

    

                                             

 

ED3/ED4-RFID V1.30 

   

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7 

www.skidweigh.com

   

IMPORTANT NOTE:   
Please read first the HID ProxPoint Plus card 
reader information on the end of this manual 
referring to the programming method that is 
required to get the system up and running. 
         

RFID Proximity Card Reader

Содержание ED3-RFID SkidWeigh Plus Series

Страница 1: ...thorized Operator Vehicle Access Control ED3 ED4 RFID V1 30 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com IMPORTANT NOTE Please read fi...

Страница 2: ...draulic technical installer Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of...

Страница 3: ...pacities Pressure transducer installation precautions Before installation of the pressure transducer the hydraulic lift circuit must be pressure free There are two ways to do that 1 Place the forks on...

Страница 4: ...On position Brown Wire Battery negative Red Wire connect to RED wire of the pressure transducer cable Black Wire connect to BLACK wire of the pressure transducer cable White Wire connect to WHITE wir...

Страница 5: ...es BLUE and GREEN normally open SPST contacts and connect in series with vehicle seat switch wire to control vehicle usage Pressure transducer cable White Wire signal 0 to 2 5 V Black Wire signal nega...

Страница 6: ...ssure transducer cable you can quickly check the system operation Turn On ignition switch Digital LCD display will be activated showing software version and serial number With LCD display indicating I...

Страница 7: ...ific software algorithm to obtain load weight accuracy within 1 of vehicle maximum lifting capacity SkidWeigh Plus series ED3 RFID Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville...

Страница 8: ...AL date time set up Note AUTO set up refers to system utilizing a wireless RF platform with automatic date time update from IVDT Base Station communication and programming hub For the applications wit...

Страница 9: ...ID Maximum input number for vehicle ID is 4 digits Note For system used with RFID card reader maximum input number for vehicle ID is 5 digits LCD Display Aug 28 2010 12 20 23 LCD Display KEY to SCROL...

Страница 10: ...ill prompt you to erase the SDRAM all files contained on the SKidWeigh Plus ED3 IM Once you have made your selection Y or N the system will automatically bring you back to the main screen in the super...

Страница 11: ...weight in pounds and enter that value accordingly The same would apply if you want the system to show load weight in kilograms Use the known load weight in kilograms and enter that value into the syst...

Страница 12: ...pty forks to the ground The LCD display prompt you to input known calibration load weight Pick up a known load weigh and lower the loaded forks to the ground Our example of the known load weight is 20...

Страница 13: ...ion Additional step As soon as the loaded forks are lowered to the ground the LCD will prompt you to input the overload value for your vehicle operational application Input the overload value and pres...

Страница 14: ...zer warning To enter into the Supervisor Menu press F key and than number 9 key Input password 521 Follow instructions shown on the LCD display LCD Display MENU PASSWORD _ LCD Display SET IMPACTS ENTE...

Страница 15: ...or menu press F key and than number 0 Follow instructions shown on the LCD display Note Use left and right arrow key bottom left side of the keypad to choose MANUAL INQUIRY or AUTO LCD Display ENTER H...

Страница 16: ...uetooth device Bluetooth pairing options are AUTO MANUAL INQUIRY Preferable method LCD Display BLUETOOTH MODE AUTO _ LCD Display BLUETOOTH MODE INQUIRY LCD Display BLUETOOTH MODE MANUAL LCD Display SE...

Страница 17: ...round LCD display must show date and time in order to initiate weighing function Activate lift control valve and lift loaded forks just above the ground Do not manipulate the tilt side shift or move t...

Страница 18: ...weight value To initiate the weighing cycle you must lower the loaded forks to the ground and lift loaded forks just above the ground Accumulative Load Weight Total To add loads weight press Enter ke...

Страница 19: ...key after individual or total load weight you will get a printout ticket If the system is utilizing RF communication data will be send to base station TARE Function Input To set up TARE value into th...

Страница 20: ...shown on LCD display Important To reset TARE you must press F key and input number 0 and press Enter key If the current value is 500 as of example than input 0 value and Enter key LCD Display TARE CON...

Страница 21: ...ER CARD to be used by the end user to program any number of valid lift truck operator s HID cards Integrated Visual Data Technology Inc DOES NOT supply valid operator card to access the system or supp...

Страница 22: ...wn below on the picture Scan RFID MASTER CARD LCD display will show Scan first valid HID operator card The LCD display will show for the moment the value of the inputed card The LCD display will indic...

Страница 23: ...D display Keep adding cards to be deleted When all cards inputed into the system press KEY TO EXIT Note In the case that you need replacement of RFID MASTER CARD please call us at 905 469 0985 How to...

Страница 24: ...ll as Corporate 1000 cards formats LED Type Bicolored green and red Transient Surge and Reverse Voltage Protection Extra Security Recognizes card formats up to 85 bits with over 137 billion unique cod...

Отзывы: