Integra Xmart LBU-ONL 1.5K Скачать руководство пользователя страница 4

 

USER MANUAL - LBU-ONL 1.5K/2.25K/3K/4.5K  

 

 

www.xmart-Inverter.com 

VER.2211.17-One (ENG)

 

 

3.

 

SAFETY, QUALITY AND PERFORMANCE STANDARDS 

 

SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC) 

Inverter Part 1-1: General & Safety Inverter in accessible areas 

IEC/EN 62040-1 

ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE (2004/108/EC) 

 

Inverter, Part 2, Electromagnetic Compatibility: 

IEC/EN 62040-2

  

    Low Freq. Conducted Disturbances & Signals: 

IEC/EN 61000-2-2 

    Electrostatic discharge immunity Test: 

IEC/EN 61000-4-2 (Level 3) 

    Radiated radio Frequency immunity: 

IEC/EN 61000-4-3 (Level 3) 

    Electrical Fast Transient / burst immunity: 

IEC/EN 61000-4-4 (Level 4) 

    Surge immunity: 

IEC/EN 61000-4-5 (Level 4) 

    Conducted Immunity:  

IEC/EN 61000-4-6

 

    Power frequency magnetic field immunity:  

IEC/EN 61000-4-8

 

    Voltage Dips, Short Interruptions & Voltage Variations Immunity:  

IEC/EN 61000-4-11

 

PERFORMANCE: Inverter Part 3: Methods of operation, specs and test requirement 

IEC/EN 62040-3 

IT Equipment. SAFETY. Part 1: General Requirements 

IEC/EN 60950-1 

BATTERY SAFETY 

EN 50272 

FCC Part 15 (for 120V models only) 

FCC Part 15 Class A 

IP PROTECTION 

IP21 (static) 

QUALITY MANAGEMENT: 

Manufactured under: 

ISO 9001 : 2008 

ENVIRONMENTAL MANAGEMENT: 

Manufactured under: 

ISO 14001 : 2015 

TRANSPORTATION: 

IEC/EN 60068-2-32 (Drop Test) 

 IEC/EN 60068-2-64 (Vibration Test) 

 IEC/EN 60068-2-27 (Shock Test) 

WARNING: Modifications made on the product or the use of this product as a part of a more complex system not expressly approved by the party 
responsible for complia

nce could void the user’s authority to operate the equipment. It also could affect its performance and the compliance of 

regulations. XMART is not responsible of modifications made after manufacturing. 
WARNING: This is a category C2 Inverter product. In a residential environment, this product may cause radio interference, in which case the user 
may be required to take additional measures (only for 220/230/240VAC systems). 
NOTE FOR 110/120 VAC SYSTEMS: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in 
a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance 
with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely 
to cause harmful interference in which case the user will be required to correct the interference at his own expense.   

 
 

 

 

 

 

Содержание Xmart LBU-ONL 1.5K

Страница 1: ...n this manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products or...

Страница 2: ...PRODUCT DESCRIPTION 3 SAFETY QUALITY AND PERFORMANCE STANDARDS 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 Inverter CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTING 10 SO...

Страница 3: ...ect this Inverter to any of its own power outlets this could damage the unit permanently WARNING Do not connect AC motor based equipment without a careful sizing of the Inverter based on inrush curren...

Страница 4: ...14001 2015 TRANSPORTATION IEC EN 60068 2 32 Drop Test IEC EN 60068 2 64 Vibration Test IEC EN 60068 2 27 Shock Test WARNING Modifications made on the product or the use of this product as a part of a...

Страница 5: ...to drive maximum rated current For 3KVA Inverter in 120V wires must be minimum 12AWG for lengths shorter than 15m 50 feet Wiring gauge is conditioned to length temperature etc Wiring must be selected...

Страница 6: ...ace Inverter module close to original XMART Batteries Array 2 If there are check all Battery DC switches are in OFF position 3 Connect Inverter to first Battery String by using original DC cable 4 In...

Страница 7: ...ncludes 2 serial ports USB RS232 Additionally there is also a Smart Port to support different communication cards such as LAN SNMP card Dry Contacts card RS 485 card among others RS232 COMMUNICATION P...

Страница 8: ...s mode is adopted in case ON button has not been activated as soon as Inverter detects a valid AC input on its terminals If bypass mode is not enabled Inverter will simply light its LCD Outputs will k...

Страница 9: ...r output is generated by inverter BATTERY MODE A Input indicator at bottom left corner A shows Battery voltage since there is no valid AC input detected B Output indicator displays AC output generated...

Страница 10: ...ll checking of systems and batteries OFF ENTER Inverter TURN OFF Press for 2 seconds to turn Inverter off ENTER When Inverter is in configuration mode this key operates as ENTER SELECT CHECK VALUES In...

Страница 11: ...INFORMATION Displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also shows r...

Страница 12: ...ammable output powered 5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area graphically displays the power supplied by the Inverter with a 4 s...

Страница 13: ...ODE ON MUTE Used as key to navigate or changing parameters value OFF ENTER Used as ENTER key to confirm modifications SELECT Used as key to navigate or changing parameters value CONFIGURATION MENU For...

Страница 14: ...c Set values with keys 06 BYPASS ENABLE DISABLE Enables or disables BYPASS function when Inverter is off ENA ENABLE DIS DISABLE Factory set DIS 07 BYPASS INPUT VOLTAGE RANGE Valid input VOLTAGE range...

Страница 15: ...maximum recharging current in Amps 1 2 4 6 or 8 A Factory set 2 A 14 BOOSTING CHARGING VOLTAGE NO MODIFICATIONS RECOMMENDED ONLY FOR TECHNICIANS Charging voltage can be increased Adjustable Voltage 2...

Страница 16: ...DESCRIPTION AO Active Open AC Active Close BAH Battery AH BAT Battery BR Battery Replacement CBV Charger Boost Voltage CFV Charger Float Voltage CF Frequency Converter Function CHA Charger current CH...

Страница 17: ...nd codes with intermittent beeps Tipo de ALARMA SIMBOLO INTERMITENTE ALARMA SONORA OVERLOAD Inverter Load exceeds Inverter capacity 1 beep s LOW BATTERY 1 beep 2s BATTERY FAULT 1 beep 2s BATTERY REPLA...

Страница 18: ...the Inverter FAILURE CODE ICON BUS START FAIL 01 BUS OVER 02 BUS UNDER 03 Inverter SOFT START FAIL 11 Inverter VOLTAGE HIGH 12 Inverter VOLTAGE LOW 13 Inverter OUTPUT SHORT 14 BATT VOLTAGE TOO HIGH 2...

Страница 19: ...n EEPROM Failure Turn off and power off Inverter Restart Inverter If not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 Turn off and power off Inverter Disconnect all equip...

Страница 20: ...ating Inverter with higher room temperatures will short dramatically battery life IMPORTANT RECHARGING PLAN FOR LONG STORAGE If Inverter and batteries are going to be stored for long time it is mandat...

Страница 21: ...charger uses a 3 steps algorithm to care batteries 1 Constant Current During this stage charger injects a constant current meanwhile batteries increase their voltage During this stage batteries recove...

Страница 22: ...bution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is o...

Страница 23: ...xmart Inverter com VER 2211 17 One ENG 23 14 REAR PANEL 1 Standard Inverter Outlets 2 Programmable Outlets 3 AC Input 4 Surge Protected RJ45 sockets 5 Emergency Power Off connector 6 USB RS232 7 Smart...

Страница 24: ...USER MANUAL LBU ONL 1 5K 2 25K 3K 4 5K www xmart Inverter com VER 2211 17 One ENG 24 15 SPECIFICATIONS 1 2...

Страница 25: ...emperatura Almacenaje UPS w o batteries 25 to 55 C UPS with batteries 20 to 50 C CEE Schuko 1 CEE Schuko 2 CEE Schuko 2 L5 30P NEMA5 20P CE IEC EN 62040 1 RoHS ISO9001 ISO14001 IEC EN 61000 2 2 IP21 F...

Страница 26: ...n though this inverter can manage battery discharge until 10 5VDC per battery we recommend not using this feature up to the limit but using a higher cut off voltage instead This will give a shorter ba...

Страница 27: ...100AH 100AH OF STRINGS 1 2 3 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 65A 130A 195A 100A 200A 100 550 1180 1768 790 1580 2372 1235 2470 200 225 552 858 374 795 1190 590 1290 300 128 345 575 250 535 825 38...

Страница 28: ...2 3 4 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 180A 65A 130A 195A 100A 200A 150 430 970 1460 1950 655 1306 1960 1020 2040 300 194 490 765 1070 340 720 1075 523 1121 450 120 318 525 740 240 500 770 360 775...

Страница 29: ...F STRINGS 1 2 3 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 65A 130A 195A 100A 200A 200 670 1 340 2 000 655 1 306 1 960 1050 2000 400 345 730 1 090 340 720 1 075 540 1140 600 240 510 760 240 500 770 360 780...

Страница 30: ...100AH OF STRINGS 1 2 3 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 65A 130A 195A 100A 200A 300 450 1025 1500 690 1300 2000 1080 2100 600 200 500 780 350 740 1100 540 1150 900 122 325 540 245 520 800 365 790...

Страница 31: ...USA Miami FL 33196 USA sales xmart Inverter com EUROPE Sabadell Barcelona 08202 Spain sales xmart Inverter com LATAM Santiago de Chile Chile sales xmart Inverter com...

Отзывы: