Operation 

The vacuum is controlled by the pressure sensitive turquoise control button on the top of the hand piece. 
By  means  of  the  plastic  screw  opposite  the  control  button,  the  residual  suction  level  can  be  set,  which  will  prevent  dripping  of  waste 
liquids from the tip or pipette. The aspirator is factory pre-set to allow a low level of constant suction; by turning the screw one full turn 
clockwise, the valve is shut and residual vacuum is stopped. 
 

Cleaning and servicing  

The Hand Operator is entirely autoclavable. When working  with biohazardous material, 
disinfect  the  VACUBOY  with  a  70 %  solution  of  isopropanol  or  ethanol  or  a  suitable 
disinfectant before disassembling for autoclaving. Please refer to the explosion drawing. 
 
To  clean,  immerse  the  pieces  in  mild  laboratory  detergent  or  70

 % ethanol, but do not 

use  abrasives,  as  a  roughened  surface may  affect  the  smooth  operation  of  the  control 
valve.  Apply  a  thin  coat  of  MOLYKOTE  HP-870  (Dow  Corning)  lubricant  as  needed  to 
the control valve to keep the action smooth (arrow). 
 
When  working  with  salt-rich  solutions,  rinse  out  the  aspirator  hand  piece  with  distilled 
water after use to avoid build-up of dried deposits.

 

 

MOLYKOTE

 

 

Chemical compatibility 

Avoid prolonged contact (days or weeks) with: 

• concentrated inorganic acids 
• sodium hypochlorite 
• methylene chloride 
• concentrated aldehydes 
• other halogenated hydrocarbons 

Resistant to: 

• DMSO 
• ethanol/methanol 
• dimethylformamide 
• acetone 

 

Note: 

• Flushing the aspirator with ethanol immediately 

after contact with organic solvents is the best 
safeguard in all cases. 

• For o-ring replacement, use INTEGRA o-rings only

 

 

Accessories and consumables 

 

VACUBOY Hand Operator Set 155500 

 

 

 

 

 
 
 

 

 

 

 

VACUBOY Hand Operator

: hand operator (O), two aspiration adapters (A and F), rubber adapter for Pasteur 

pipettes (I),  silicone grease 

155510 

464083_V

0

6

_

OI

_V

A

CU

B

OY

 

 

VACUBOY Hand Operator Set

: hand operator (O), aspiration adapter D, A, K, L, F, rubber adapter for 

Pasteur pipettes (I), stand for hand operator (P), silicone tubing 1800 mm, silicone grease 

155500 

1-channel stainless steel aspiration adapter 40 mm 

155502 

1-channel stainless steel aspiration adapter 150 mm 

155522 

1-channel stainless steel aspiration adapter 280 mm 

155525 

1-channel aspiration adapter for disposable tips/GripTips (with locking) 

155504 

1-channel aspiration adapter for disposable tips/GripTips (pack of 5) 

159023 

1-channel aspiration adapter with ejector for disposable tips/GripTips (with locking)  

155526 

1-channel aspiration adapter with ejector for disposable tips 

159026 

1-channel aspiration adapter with ejector GripTips 

159027 

Rubber adapter for Pasteur pipettes 

155505 

4-channel stainless steel aspiration adapter 40 mm 

155524 

8-channel stainless steel aspiration adapter 40 mm 

155503 

8-channel aspiration adapter with ejector for disposable tips (with locking)  

155520 

8-channel aspiration adapter with ejector for disposable tips 

159024 

8-channel aspiration adapter with ejector for GripTips 

159025 

Stand for VACUBOY hand operator 

155501 

 

Silicone tubing 1800 mm 

158332 

Stand for PIPETBOY (

acu

 or 

pro

) and VACUBOY 