4. UPS DESCRIPTION 

 

 
This kind of equipment is known as UPS (Uninterruptible Power Supply). It has 2 main functions: give electrical 
protection against surges, spikes and some other dangerous failures of electrical main system and also 
provides electrical backup based on internal batteries. In that way products you connect to your UPS will be 
protected and will receive electrical energy even during failures of main electrical AC system. 
This UPS is designed to satisfy all requirements of Personal Computers (PCs). It includes internal voltage 

regulator to stabilize input AC variations without using internal batteries. Only in presence of important input 
failures UPS will use internal batteries to provide energy in outlet sockets. In this way batteries life expectancy is 
longer. 
 

 
 
 
 
 
 
 

 
 
 
 
 
 

1.- Output sockets 

4.- RJ-11 protected sockets 

2.- Input AC 

5.- USB port 

3.- Input breaker 

6.- USB in 120V models could be optional 

 
 

 
As mentioned this UPS will provide backup energy in its outlets when main AC input fails. Runtime will depend 
on some different factors: 

 

 

Battery charging level. 

 

Battery capacity according to the use given and lifetime. 

 

Load consumption connected to UPS outlets. Higher the output load shorter the runtime. 
 

Under normal condition, when UPS is ON and connected to AC source, UPS will keep batteries fully charged. 

 
 
 
 
WARNING: 
 
This UPS is not compatible with power plants and generators. Do not connect this UPS to outlets supplied 
by power plants / generators. 
 
 
 

USER MANUAL - 

EPLUS 501/701/901

   

ENGLISH

 

________________________________________________________ 

www.integra-ups.com                                                                                                        1303-EPLUS 501/701/901-ENG   - 

5

 

 

5. UPS INSTALLATION 

 

 

 

This UPS must be installed indoor with controlled environment free of excessive dust, corrosive air or 
conductive dust. 

 

Do not install in outdoor. Keep UPS working under operational conditions listed in specifications table of 
this manual. Keep out of direct sun light, water and heat sources.  

 

Do not install UPS close to PC screen to avoid interference. UPS must be at least at 20cm from screen. 

 

Connect TEL line to RJ11 port in this UPS identified as IN. Connect router input to RJ-11 port in this UPS 
identified as OUT 

 

Plug  power cord of this UPS to AC source socket. 

 

Plug your products to UPS outlets. 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
IMPORTANT WARNINGS: 

 

Make sure UPS is plugged to AC source compatible with UPS electrical specifications. Check UPS specs 
in UPS label. 

 

Make sure your products input voltage is compatible with UPS voltage output. 

 

Check total load in Watts to be connected to UPS is not higher to maximum UPS capacity. 

 

Do NOT plug neither laser printers nor copiers to this UPS. This equipments are high load products will 
overload your UPS. 

 
 

6. UPS OPERATION 

 

 

 

Once UPS is installed and connected according to section 4 of this  manual,  please  turn  UPS  on  by 
ON/OFF button in front panel. Front panel green LED must turns ON. 

 

Turn your products ON one by one. 

 

After finishing your products will be fully protected by the UPS. 

 
This UPS has COLD-START function that allows to turn UPS on even during a failure in the main AC source. 

 
Front panel LED will let you know UPS status: OFF / ON / BATTERY MODE. 
 
 