Quick installation manual for Brushless DC motor drive. Model BLD15___Versione 01/19
6
OUTPUT
There are two NPN outputs open collector. Can be used as open collector outputs (if equipped with PLC which
accepts the NPN output), or with a resistance R = 10 KOHM (one for each output) to get a voltage signal. 50
V & 100 mA NPN outputs, MAX.
Note: The FAULT output is normally closed. It opens when an alarm happens. In the case of the pull up
resistor, the alarm output is a voltage (+12 Vdc signal).
The signal is output at the point of the arrow (see diagram below).