The table shows the assignment of the relay numbers and of the analog in/outputs to the EP module addresses.

Symbol Description

Default

Function

Module 

Address

Analog 

Input

Relay 

No.

Analog 

Output Module

EP- Mod. 0 Relay + SP

Relay + SP active = 

Alarm relay + analog 

inputs active

01-04

01-05

01-02

GC-05

EP- Mod. 1 Inactive

Inactive = Module not active

Relay active = 

Only alarm relay active

Relay + SP active = 

Alarm relay + analog 

inputs active

1

05-08

06-10

03-04

EP-05

EP- Mod. 2 Inactive

2

09-12

11-15

05-06

EP-05

EP- Mod. 3 Inactive

3

13-16

16-20

07-08

EP-05

EP- Mod. 4 Inactive

4

17-20

21-25

09-10

EP-05

EP- Mod. 5 Inactive

5

 21-24

26 -30

11-12

EP-05

4.8.14  Error Indicator System Bus

All data packets received by the GC-05 are checked for completeness and compatibility. Faulty data packets are 

recorded by the error counter. Max. 1-2 faulty data packets are admissible a day.

A higher error rate mostly comes from incorrect wiring of the field bus line.

4.8.15  Analog Output

The Gas Controller Module as well as the EP-05 Modules 1 to 5 have two analog outputs (AO) with 4 to 20 mA signal 

each. The signal of one or more sensor points can be assigned to each of the analog outputs. The assignment is 

effected in the menu “SP Parameter” for each SP. The sensor point sends the signal, which is defined in the menu 

“C/A Mode”.

Out of the signals of all assigned sensor points the Gas Controller determines the minimum, the maximum

or the average value and displays it at the analog output. The definition, which value is transmitted, is effected in the 

menu “Analog Output X”.

The analog output can be calibrated at 4 and at 20 mA. Therefore an ampere meter (measuring range 25 mA) can be 

attached to the AO and the respective factor has to be changed until the analog output corresponds to 4 and/or 20 mA. 

During calibration evaluation of the sensor point signals is not possible. This calibration is effected by the factory. The 

factors should not be changed.

 

Symbol

Description

Default Status Function

Max.

Select 

Output mode

Max.

Min. 

= Displays the minimum value of all assigned SP 

Max. 

= Displays the maximum value of all assigned SP 

Average  = Displays the average value of all assigned SP

4.0 

20.0

Calibration

4.0 

20.0

4.0  = Calibration factor at 4 mA 

20.0 = Calibration factor at 20 mA 

Содержание PolyGard MGC2-04

Страница 1: ...Ph 858 578 7887 888 GO INTEC relevantsolutions com inteccontrols August 11 2016 Revision PolyGard is a registered trademark of MSR Electronic GmbH BUILDING SOLUTIONS Analog Gas Controller PolyGard MG...

Страница 2: ...Sensor Readings 11 4 5 Menu Relay Parameter 12 4 5 1 Relay Mode 12 4 5 2 Relay Function Static Flash 12 4 5 3 Latching Mode 13 4 5 4 Horn Function 13 4 5 5 External Operation of Alarm Relay 14 4 5 6 D...

Страница 3: ...rd Maintenance 27 4 8 9 GC Address 27 4 8 10 Define the Failure Relay 28 4 8 11 Acknowledge a Relay in Latching Mode by a DI 28 4 8 12 Power On Time 28 4 8 13 Registration of Expansions Modules 28 4 8...

Страница 4: ...of up to 24 analog transmitters Up to five free programmable alarm thresholds are available for each transmitter For transmitting the alarms there are up to 30 relays with potential free change over...

Страница 5: ...nters sub menus and saves parameter settings Scrolls up down within a menu changes a value Moves the cursor position LED orange Flashes when alarm one or more alarms are active Permanently on when at...

Страница 6: ...authorized intervention All menu windows are visible without entering a code The release of a code level is canceled if no button is pushed within 15 minutes The code levels are classified in order of...

Страница 7: ...EC 13 06 13 1 45am Display of gas concentration Power On Time Power On Time Main menu After 30 sec Starting menu System Setup Reading and change of the system parameters See Section 4 7 Data Logger Re...

Страница 8: ...Parameter are activated in addition 4 1 1 Acknowledge a Fault Attention Acknowledging of a fault is only possible after having removed the cause In order to recognize situations where errors and faul...

Страница 9: ...defective Solution Check cable to analog transmitter make calibration replace the analog transmitter GC Error EP00 Error Internal communication error I O Board to LCD Board Cause Internal error RS 485...

Страница 10: ...OFF OFF Relay OFF no gas alarm ON Relay ON gas alarm Manual OFF Relay manual OFF Manual ON Relay manual ON Latching mode Relay in latching mode 4 3 1 Manual Operation of the Relays The manual operatio...

Страница 11: ...ues CV and AV are displayed The SP address and the display depend on the system parameter settings for the SP addressing mode see 4 8 3 SP01 CO ppm 50 AV 33 CV Symbol Description Setting Status Functi...

Страница 12: ...ing Mode No Activation of latching mode See 4 5 3 Static Flash 0 s Relay function See 4 5 2 Relay Mode De energized Relay mode See 4 5 1 Relay Parameter Main menu R 01 Selection relay No only register...

Страница 13: ...enu Status Relay or Digital Input On Off 4 5 4 Horn Function The horn function is only activated if at least one of the two parameters time or digital input is set This function has priority to the la...

Страница 14: ...priority to a gas alarm and or manual switching in the menu Status Relay and is subordinate to the switching of static flashing and energized de energized modes If external ON and OFF are parameterize...

Страница 15: ...rameter settings for the GC mode see 4 7 3 Threshold 2 100 ppm Define threshold 2 See 4 6 6 Threshold 3 120 ppm Define threshold 3 See 4 6 6 Threshold 1 80 ppm Define threshold 1 See 4 6 6 SP Signal L...

Страница 16: ...t Selection SP No analog transmitter Active SP Status not active active Sensor point activated at the controller not active Sensor point not activated at the controller 4 6 2 Lock or Unlock SP This fu...

Страница 17: ...uality Refrigerant gas Refrigerant gas Refrigerant gas Refrigerant gas Refrigerant gas Refrigerant gas Temperature Humidity Carbon dioxide3 Toxic gas Temperature ppm LEL ppm ppm ppm Vol ppm ppm ppm pp...

Страница 18: ...output signal Non linear Transmitter with non linear output signal semiconductor 4 6 6 Threshold Hysteresis For each sensor point five alarm thresholds are available for free definition If the gas con...

Страница 19: ...1 2 3 4 5 Fault 1 1 0 0 0 Failure SP 1 1 0 0 0 0 Alarm not ON at SP failure 1 Alarm ON at SP failure 4 6 10 Alarm Assigned to Alarm Relay Each of the 5 alarms can be assigned to any alarm relay Unused...

Страница 20: ...an USB device at the USB cable to use the data logger function This USB device may be for example an USB flash drive In this menu the parameters for the long term recording of the USB device are set...

Страница 21: ...ished PC programs Internal structure of the file The headlines and column numbers are only for easy explanation and aren t written in the file Column 1 2 3 4 5 6 7 8 9 10 etc Time SP1 SP2 SP3 SP4 SP5...

Страница 22: ...be too big to be still edited by established PC programs Internal structure of the file The headlines are not written in the file Time SP Gas CV AV A1 A1R A2 A2R A3 A3R A4 A4R A5 A5R 09_49_47 SP 02 C...

Страница 23: ...s and faults Internal structure of the file The headlines are not written in the file Current time Source Error date time Error type 10_22_28 SP 24 03_30 10_20 SP 24 error 13_48_28 SP 24 03_30 13_46 S...

Страница 24: ...m Parameter Display and changes of the system parameter for the Gas Controller Next Maint Date MM DD YY See 4 8 5 Language English See 4 8 4 AV Time 1800 s See 4 8 6 Date MM DD YY See 4 8 7 Service Pa...

Страница 25: ...P active See 4 8 13 Power ON time 30 s See 4 8 12 Correct Error 0 0 See 4 8 14 Latching Reset DI 0 See 4 8 11 EP Module X Inactive See 4 8 13 Fault Relay 04 See 4 8 10 EP Module 1 Inactive See 4 8 13...

Страница 26: ...Symbol Description Default Status Function 98 Addr a 1 SP SP Addr Mode 98 Addr a 1 SP 98 Addr a 1 SP transmitters 4 8 4 Language This configurable functionality is available from version 9 02 Selecti...

Страница 27: ...elay time of average value overlay 0 No overlay function ppm Threshold average overlay 1800 s AV Time 1800 s sec Time for calculating the average value 4 8 7 System Time System Date Input and correcti...

Страница 28: ...er On Time Gas sensors need a running in period until the chemical process of the sensor reaches stable conditions During this running in period the current signal can lead to an unwanted releasing of...

Страница 29: ...m incorrect wiring of the field bus line 4 8 15 Analog Output The Gas Controller Module as well as the EP 05 Modules 1 to 5 have two analog outputs AO with 4 to 20 mA signal each The signal of one or...

Страница 30: ...nual intervention on IN or Out relays in the menu Relay Status or via external DI will only affect the single relay Symbol Description Default Status Function 0 30 In Relay 0 0 Function off X Relay X...

Страница 31: ...ons 5 1 Configuration Parameter Card Commission Project No Customer Startup Company Startup Date Service Technician 5 1 1 System Setup Configuration Service Software Version Maint Date Service Phone A...

Страница 32: ...olyGard is a registered trademark of MSR Electronic GmbH 5 1 3 Relay Setup Available Relay Outputs max MGC2 04 5 MGC2 08 10 MGC2 12 15 MGC2 16 20 MGC2 20 20 MGC2 24 20 Relay No Mode Steady Flash Latch...

Страница 33: ...nsor Setup Available Analog Inputs max MGC2 04 4 MGC2 08 8 MGC2 12 12 MGC2 16 16 MGC2 20 20 MGC2 24 24 SP No SP Status Type Measuring Range SP Signal Stage Setpoints Hyst Delay Time sec CV AV Assigned...

Страница 34: ...sensors that are out of calibration and fans that have been left in hand mode manually off or manually on either at the motor control panel or in the gas controller s configuration Recommissioning ty...

Отзывы: